Literature DB >> 21168547

Stripping voltammetric detection of mercury(II) based on a surface ion imprinting strategy in electropolymerized microporous poly(2-mercaptobenzothiazole) films modified glassy carbon electrode.

Xu-Cheng Fu1, Xing Chen, Zheng Guo, Cheng-Gen Xie, Ling-Tao Kong, Jin-Huai Liu, Xing-Jiu Huang.   

Abstract

This work reports a surface ion imprinting strategy in electropolymerized microporous poly(2-mercaptobenzothiazole) (MPMBT) films at the surface of glassy carbon electrode (GCE) for the electrochemical detection of Hg(II). The Hg(II)-imprinted MPMBT/GCE exhibits larger binding to functionalized capacity, faster binding kinetics and higher selectivity to template Hg(II) due to their high ratio of surface-imprinted sites, larger surface-to-volume ratios, the complete removal of Hg(II) templates and larger affinity to Hg(II). The square wave anodic stripping voltammetry (SW ASV) response of the Hg(II)-imprinted MPMBT/GCE to Hg(II) is ca. 3.0 and 5.9 times larger than that at the direct imprinted poly(2-mercaptobenzothiazole) modified GCE and non-imprinted MPMBT/GCE sensor, respectively; and the detection limit for Hg(II) is 0.1nM (which is well below the guideline value given by the World Health Organization). Excellent wide linear range (1.0-160.0nM) and good repeatability (relative standard deviation of 2.5%) were obtained for Hg(II). The interference experiments showed that mercury signal was not interfered in the presence of Pb(II), Cd(II), Zn(II), Cu(II) and Ag(I), respectively. These values, particularly the high sensitivity and excellent selectivity compared favorably with previously reported methods in the area of electrochemical Hg(II) detection, demonstrate the feasibility of using the prepared Hg(II)-imprinted MPMBT/GCE for efficient determination of Hg(II) in aqueous environmental samples.
Copyright © 2010 Elsevier B.V. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 21168547     DOI: 10.1016/j.aca.2010.11.020

Source DB:  PubMed          Journal:  Anal Chim Acta        ISSN: 0003-2670            Impact factor:   6.558


  5 in total

1.  Determination of subnanomolar levels of mercury (II) by using a graphite paste electrode modified with MWCNTs and Hg(II)-imprinted polymer nanoparticles.

Authors:  Taher Alizadeh; Negin Hamidi; Mohamad Reza Ganjali; Faride Rafiei
Journal:  Mikrochim Acta       Date:  2017-12-05       Impact factor: 5.833

2.  Detection of silver through amplified quenching of fluorescence from polyvinyl pyrrolidone-stabilized copper nanoclusters.

Authors:  Deyuan Yang; Ting Zhou; Yifeng Tu; Jilin Yan
Journal:  Mikrochim Acta       Date:  2021-05-29       Impact factor: 5.833

Review 3.  Modified electrodes used for electrochemical detection of metal ions in environmental analysis.

Authors:  Gregory March; Tuan Dung Nguyen; Benoit Piro
Journal:  Biosensors (Basel)       Date:  2015-04-29

4.  A molecular-gap device for specific determination of mercury ions.

Authors:  Zheng Guo; Zhong-Gang Liu; Xian-Zhi Yao; Kai-Sheng Zhang; Xing Chen; Jin-Huai Liu; Xing-Jiu Huang
Journal:  Sci Rep       Date:  2013-11-01       Impact factor: 4.379

Review 5.  From Electrochemical Biosensors to Biomimetic Sensors Based on Molecularly Imprinted Polymers in Environmental Determination of Heavy Metals.

Authors:  Cosimino Malitesta; Sabrina Di Masi; Elisabetta Mazzotta
Journal:  Front Chem       Date:  2017-07-06       Impact factor: 5.221

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.