Patient satisfaction and dissatisfaction with mandibular two-implant overdentures using different attachment systems: 5-year outcomes.

Mohammed I Al-Zubeidi1, Nabeel H M Alsabeeha, W Murray Thomson, Alan G T Payne.   

Abstract

BACKGROUND: Different attachment systems for mandibular two-implant overdentures could influence levels of patient satisfaction. Positive consensus of the majority of patients being satisfied does not preclude the possibility of dissatisfaction for some.
PURPOSE: To evaluate patient satisfaction and dissatisfaction before and after 5 years of wearing mandibular two implant overdentures using different attachment systems ; to determine the prognostic relevance of pretreatment complete denture complaints to treatment outcomes.
MATERIALS AND METHODS: A total of 106 edentulous participants enrolled in a clinical trial completed a preliminary self-report inventory of their original complete denture complaints.New complete maxillary dentures and mandibular two-implant overdentures were provided to each participant using one of six different attachment systems. Patient satisfaction was determined at pretreatment; at baseline with mandibular two-implant overdenture insertion; and then annually for 5 years, using visual analogue and Likert-type scales.
RESULTS: Patient satisfaction with mandibular two-implant overdentures showed significant changes pre- to posttreatment(baseline) in all domains, but these were significant immediately and maintained without further significance for 5 years, other than pain with the overdenture. After 5 years, no significant differences were observed with all the attachment systems. Highly significant differences were found with some social and psychological aspects by the fifth year compared to baseline. Diagnostic and prognostic indicators from a pretreatment inventory identified 12 participants (13.5%) who were dissatisfied. These indicators revealed a maladaptive predisposition to mandibular two-implant overdentures.
CONCLUSIONS: The provision of mandibular two-implant overdentures will, in the majority of patients, significantly enhance levels of patient satisfaction for 5 years, as compared to complete mandibular dentures, regardless of the attachment system. Careful evaluation of pretreatment complaints with conventional dentures can possibly identify patient dissatisfaction with mandibular two-implant overdentures [corrected].
© 2010 Wiley Periodicals, Inc.

Entities:  

Mesh:

Year:  2010        PMID: 21166990     DOI: 10.1111/j.1708-8208.2010.00306.x

Source DB:  PubMed          Journal:  Clin Implant Dent Relat Res        ISSN: 1523-0899            Impact factor:   3.932


  3 in total

Review 1.  Comparison of immediate and conventional loading protocols with respect to marginal bone loss around implants supporting mandibular overdentures: A systematic review and meta-analysis.

Authors:  Minoru Sanda; Kenji Fueki; Pranjal Radke Bari; Kazuyoshi Baba
Journal:  Jpn Dent Sci Rev       Date:  2018-10-24

2.  Clinical and satisfaction outcomes of using one or two dental implants for mandibular overdentures: preliminary short-term follow-up of a randomized clinical trial.

Authors:  Kássia Estefania Hauck; Micheline Sandini Trentin; Tarcio Hiroshi Ishimine Skiba; Jamil Awad Shibli; João Paulo De Carli
Journal:  Int J Implant Dent       Date:  2021-02-11

3.  Interventions for replacing missing teeth: attachment systems for implant overdentures in edentulous jaws.

Authors:  Alan Gt Payne; Nabeel Hm Alsabeeha; Momen A Atieh; Marco Esposito; Sunyoung Ma; Marwah Anas El-Wegoud
Journal:  Cochrane Database Syst Rev       Date:  2018-10-11