Literature DB >> 21166681

Detection of human platelet antigen-1a alloantibodies in cases of fetomaternal alloimmune thrombocytopenia using recombinant β3 integrin fragments coupled to fluorescently labeled beads.

Winnie Chong1, Paul Metcalfe, Rosey Mushens, Geoff Lucas, Willem H Ouwehand, Cristina V Navarrete.   

Abstract

BACKGROUND: Testing for alloantibodies against human platelet antigens (HPAs) is essential for the clinical diagnosis of fetomaternal alloimmune thrombocytopenia (FMAIT), posttransfusion purpura, and platelet (PLT) refractoriness. Most of the methods currently used for HPA alloantibody detection rely on the availability of panels of HPA-typed PLTs and some rely on validated monoclonal antibodies (MoAbs) against the PLT glycoproteins. Recombinant β3 integrins displaying the HPA-1a (rHPA-1a) or HPA-1b (rHPA-1b) epitopes have been produced as an alternative source of antigen. The suitability of these integrin fragments was evaluated for the development of an HPA-1a alloantibody screening assay, using Luminex xMAP technology. STUDY DESIGN AND METHODS: A 3-plex bead assay was developed by coupling biotinylated rHPA-1a, rHPA-1b, and recombinant glycoprotein VI to LumAvidin microspheres. Forty patient samples referred for FMAIT diagnostic testing, which were previously screened by the MoAb-specific immobilization of PLT antigens (MAIPA) assay, were used to assess the assay.
RESULTS: The rHPA-1a- and rHPA-1b-coupled beads were able to detect HPA-1a and HPA-1b alloantibodies in all patient samples tested that were previously confirmed to contain HPA-1-specific antibodies. Furthermore, HLA Class I antibodies did not cross-react with the coupled beads.
CONCLUSION: The 3-plex bead assay can be used to detect HPA-1a antibodies with sufficient specificity and sensitivity for use in the clinical setting of FMAIT. The development of other recombinant integrin fragments with the use of Luminex xMAP technology may assist in providing more rapid HPA antibody detection, enabling prompt diagnosis of alloimmune PLT disorders.
© 2010 American Association of Blood Banks.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 21166681     DOI: 10.1111/j.1537-2995.2010.02977.x

Source DB:  PubMed          Journal:  Transfusion        ISSN: 0041-1132            Impact factor:   3.157


  2 in total

1.  A novel assay for the detection of anti-human platelet antigen antibodies (HPA-1a) based on peptide aptamer technology.

Authors:  Julien Thibaut; Yves Mérieux; Dominique Rigal; Germain Gillet
Journal:  Haematologica       Date:  2011-12-01       Impact factor: 9.941

2.  Novel method for simultaneously detecting HPA and HLA antibodies using Luminex microbeads.

Authors:  Sudan Tao; Shu Chen; Xiaozhen Hong; Ji He; Faming Zhu
Journal:  J Transl Med       Date:  2019-08-05       Impact factor: 5.531

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.