A unique failure mechanism of a distal radius fracture fixed with volar plating--a case report.

William Min1, Kevin Kaplan, Ryan Miyamoto, Nirmal C Tejwani.   

Abstract

Various treatment options exist for distal radius fractures, and the complications associated with operative and nonoperative management are well documented in the literature. While surgical management with the use of various buttress and locked plating constructs has gained popularity, the long-term outcomes of these plating techniques have not yet significantly demonstrated improved outcomes, as compared to adequately reduced nonoperative measures. Furthermore, this operative technique can be associated with failures and complications. We present a case report of one volar-plate construct requiring revision, secondary to loss of fracture reduction, with no evidence of implant loosening or failure. A literature review on the complications associated with these plate constructs is also presented.

Entities:  

Mesh:

Year:  2010        PMID: 21162709

Source DB:  PubMed          Journal:  Bull NYU Hosp Jt Dis        ISSN: 1936-9719


  1 in total

1.  Distal radius re-fracture with bending of implant and neurovascular compromise.

Authors:  Rafiq Kanji; James Nutt; Spiros Stavropoulos; Ahmed Elmorsy; Hank J Schneider
Journal:  J Clin Orthop Trauma       Date:  2017-08-23