Literature DB >> 21162592

On-line electrodialytic salt removal in electrospray ionization mass spectrometry of proteins.

Yongjing Chen1, Masanobu Mori, Amanda C Pastusek, Kevin A Schug, Purnendu K Dasgupta.   

Abstract

Salts and buffers, commonly used in isolation and stabilization of biological analytes, have a deleterious effect on electrospray ionization mass spectrometry (ESI-MS). Excessive concentrations of salts lead to ion suppression and adduct formation, which mask or complicate ion signals. In this work, we describe a salt remover (SR), configured as a three-compartment flow-through system, where the central compartment is separated from the outer compartments by a cation-exchange membrane (CEM) and an anion-exchange membrane (AEM). One platinum electrode is placed in each of the outer compartments, where water or electrolyte is flowing. The CEM electrode is held at a negative potential relative to the AEM side; cations/anions migrate by electrophoresis to the CEM/AEM receiver liquids, respectively. Proteins have poorer electrophoretic mobility relative to the buffer components, permitting removal of the salt. The salt-free proteins proceed to the ESI source. The capillary scale SR (internal volume 2.5 μL) described here effectively desalted continuous flows of NaCl solutions (200 mequiv/L at 1 μL/min, equivalent to a flux of 200 nequiv/min with 88% efficiency) and achieved >99.8% salt removal with 154 mM NaCl (isotonic saline) at 1 μL/min. With optimized current, >80% of concurrently present 20 μM protein was transmitted. Desalting efficiency and analyte loss was evaluated with different salt concentration and flow rate combinations under different applied current. Good-quality ESI-MS spectra of cytochrome c, myoglobin, and lysozyme as test proteins in a saline solution, passed through the SR, are demonstrated.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 21162592     DOI: 10.1021/ac102809c

Source DB:  PubMed          Journal:  Anal Chem        ISSN: 0003-2700            Impact factor:   6.986


  5 in total

1.  Selective removal of alkali metal cations from multiply-charged ions via gas-phase ion/ion reactions using weakly coordinating anions.

Authors:  Carl A Luongo; Jiexun Bu; Nicole L Burke; Joshua D Gilbert; Boone M Prentice; Steven Cummings; Christopher A Reed; Scott A McLuckey
Journal:  J Am Soc Mass Spectrom       Date:  2015-01-06       Impact factor: 3.109

2.  Rapid online buffer exchange for screening of proteins, protein complexes and cell lysates by native mass spectrometry.

Authors:  Zachary L VanAernum; Florian Busch; Benjamin J Jones; Mengxuan Jia; Zibo Chen; Scott E Boyken; Aniruddha Sahasrabuddhe; David Baker; Vicki H Wysocki
Journal:  Nat Protoc       Date:  2020-01-31       Impact factor: 13.491

3.  Surface-Induced Dissociation: An Effective Method for Characterization of Protein Quaternary Structure.

Authors:  Alyssa Q Stiving; Zachary L VanAernum; Florian Busch; Sophie R Harvey; Samantha H Sarni; Vicki H Wysocki
Journal:  Anal Chem       Date:  2018-12-18       Impact factor: 6.986

4.  Addition of Serine Enhances Protein Analysis by DESI-MS.

Authors:  Roshan Javanshad; Elahe Honarvar; Andre R Venter
Journal:  J Am Soc Mass Spectrom       Date:  2019-02-15       Impact factor: 3.109

5.  Rapid and flexible online desalting using Nafion-coated melamine sponge for mass spectrometry analysis.

Authors:  Chong Li; Amanda DeVor; Jing Wang; Stephen J Valentine; Peng Li
Journal:  Rapid Commun Mass Spectrom       Date:  2022-09-15       Impact factor: 2.586

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.