Literature DB >> 21157764

Broken Kirschner or guide-wire retrieval: a report of 4 cases.

Ramesh Kumar Sen1, Sujit Kumar Tripathy, Sameer Aggarwal, Amit Agarwal, Tarun Goyal, Naveen Tahasildar, Sarvdeep Dhatt.   

Abstract

Migration of a broken wire into the hip joint or pelvis during surgery is rare, but it can cause significant complications. Retrieval can be extremely difficult and hazardous. We report 4 cases of broken Kirschner or guide wire removal around the hip joint. Two wires were inside the hip joint and two had protruded into the pelvis. The problems encountered and techniques used for retrieval are discussed.

Mesh:

Year:  2010        PMID: 21157764     DOI: 10.1177/112070001002000422

Source DB:  PubMed          Journal:  Hip Int        ISSN: 1120-7000            Impact factor:   2.135


  2 in total

1.  Intrapelvic Protrusion of a Broken Guide Wire Fragment during Fixation of a Femoral Neck Fracture.

Authors:  Ahmadreza Afshar
Journal:  Arch Bone Jt Surg       Date:  2017-01

2.  Intrapelvic Protrusion of a Broken Guide Wire Fragment during Fixation of a Femoral Neck Fracture.

Authors:  Uttam Chand Saini; Nirmal Raj Gopinathan; Sameer Aggarwal; Ramesh Sen
Journal:  Arch Bone Jt Surg       Date:  2018-03
  2 in total