| Literature DB >> 21154884 |
Nageswara Rao Pilli1, Jaswanth Kumar Inamadugu, Neeraja Kondreddy, Vijaya Kumari Karra, Rajasekhar Damaramadugu, J V L N Seshagiri Rao.
Abstract
A rapid and sensitive liquid chromatography-tandem mass spectrometric (LC-MS/MS) assay method has been developed and fully validated for simultaneous quantification of donepezil and its active metabolite, 6-o-desmethyl donepezil in human plasma. Analytes and the internal standard were extracted from human plasma by liquid-liquid extraction technique using a 30:70 v/v mixture of ethyl acetate and n-hexane. The reconstituted samples were chromatographed on a C(18) column by using a 70:30 v/v mixture of acetonitrile and ammonium formate (5 mm, pH 5.0) as the mobile phase at a flow rate of 0.6 mL/min. The calibration curve obtained was linear (r ≥ 0.99) over the concentration range of 0.09-24.2 ng/mL for donepezil and 0.03-8.13 ng/mL for 6-o-desmethyl donepezil. The results of the intra-day and inter-day precision and accuracy studies were well within the acceptable limits. The proposed method was successfully applied for the estimation of the drug in real time plasma samples for pharmacokinetic studies.Entities:
Mesh:
Substances:
Year: 2010 PMID: 21154884 DOI: 10.1002/bmc.1552
Source DB: PubMed Journal: Biomed Chromatogr ISSN: 0269-3879 Impact factor: 1.902