Literature DB >> 21154673

Effects of cochlear drilling with Piezosurgery Medical device in rats.

Karen S Pawlowski1, Elena Koulich, Domenico Cuda, Charles G Wright, Elisa Stabilini, Peter S Roland.   

Abstract

OBJECTIVES/HYPOTHESIS: Drilling on the otic capsule for cochleostomy should be less traumatic to the cochlea with the Piezosurgery Medical device (PZ) than with a standard diamond drill (DD). "Soft" cochleostomy is used for preservation of residual hearing in cochlear implant patients. PZ drilling can be used for accurate cochleostomy placement with minimal soft-tissue damage and may be superior for atraumatic drilling on the cochlea, as compared with a DD. This study compared inner ear effects after drilling the rat otic capsule with the PZ versus the DD. STUDY
DESIGN: Prospective animal study using rats.
METHODS: Otic capsule drilling was performed on the left ear with the DD (n = 5) or the PZ (n = 5), while otic capsule temperature was monitored. Contralateral ears served as controls. The animals were sacrificed after 1 week. Organ of Corti damage was morphologically evaluated and compared between groups.
RESULTS: Basal turn hair cell loss was observed in all ears in the PZ group, regardless of drilling depth. However, no cochlear damage was found in any ears in the DD group.
CONCLUSIONS: Otic capsule drilling with the PZ results in greater trauma to the rat inner ear than drilling using conventional methods.

Entities:  

Mesh:

Year:  2011        PMID: 21154673     DOI: 10.1002/lary.21166

Source DB:  PubMed          Journal:  Laryngoscope        ISSN: 0023-852X            Impact factor:   3.325


  5 in total

1.  Cochlear implantation updates: the Dallas Cochlear Implant Program.

Authors:  Emily A Tobey; Lana Britt; Ann Geers; Philip Loizou; Betty Loy; Peter Roland; Andrea Warner-Czyz; Charles G Wright
Journal:  J Am Acad Audiol       Date:  2012-06       Impact factor: 1.664

2.  [Aspects of inner ear trauma in CI treatment].

Authors:  T Klenzner
Journal:  HNO       Date:  2011-06       Impact factor: 1.284

Review 3.  [Piezoelectric ear surgery: a systematic review. German version].

Authors:  Stefan Lyutenski; Anja Lieder; Marc Bloching
Journal:  HNO       Date:  2022-08-12       Impact factor: 1.330

Review 4.  Piezoelectric ear surgery: a systematic review.

Authors:  Stefan Lyutenski; Anja Lieder; Marc Bloching
Journal:  HNO       Date:  2022-10-07       Impact factor: 1.330

5.  Ultrasonic bone removal from the ossicular chain affects cochlear structure and function.

Authors:  Jennifer M Siu; Jaina Negandhi; Robert V Harrison; Nikolaus E Wolter; Adrian James
Journal:  J Otolaryngol Head Neck Surg       Date:  2021-04-02
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.