Literature DB >> 21154108

Physiological responses to wearing a prototype firefighter ensemble compared with a standard ensemble.

W Jon Williams1, Aitor Coca, Raymond Roberge, Angie Shepherd, Jeffrey Powell, Ronald E Shaffer.   

Abstract

This study investigated the physiological responses to wearing a standard firefighter ensemble (SE) and a prototype ensemble (PE) modified from the SE that contained additional features, such as magnetic ring enclosures at the glove-sleeve interface, integrated boot-pant interface, integrated hood-SCBA facepiece interface, and a novel hose arrangement that rerouted self-contained breathing apparatus (SCBA) exhaust gases back into the upper portion of the jacket. Although the features of the PE increased the level of encapsulation of the wearer that could lead to increased physiological stress compared with the SE, it was hypothesized that the rerouted exhaust gases provided by the PE hose assembly would (1) provide convective cooling to the upper torso, (2) reduce the thermal stress experienced by the wearer, and (3) reduce the overall physiological stress imposed by the PE such that it would be either less or not significantly different from the SE. Ten subjects (seven male, three female) performed treadmill exercise in an environmental chamber (22°C, 50% RH) at 50% [image omitted]O(2max) while wearing either the SE with an SCBA or the PE with an SCBA either with or without the hose attached (designated PEWH and PENH, respectively). Heart rate (HR), rectal and intestinal temperatures (T(re), T(in)), sweat loss, and endurance time were measured. All subjects completed at least 20 min of treadmill exercise during the testing. At the end of exercise, there was no difference in T(re) (p = 0.45) or T(in) (p = 0.42), HR, or total sweat loss between the SE and either PEWH or PENH (p = 0.59). However, T(sk) was greater in PEWH and PENH compared with SE (p < 0.05). Total endurance time in SE was greater than in either PEWH or PENH (p < 0.05). Thus, it was concluded that the rerouting of exhaust gases to the jacket did not provide significant convective cooling or reduce thermal stress compared with the SE under the mild conditions selected, and the data did not support the hypotheses of the present study.

Entities:  

Mesh:

Year:  2011        PMID: 21154108     DOI: 10.1080/15459624.2011.538358

Source DB:  PubMed          Journal:  J Occup Environ Hyg        ISSN: 1545-9624            Impact factor:   2.155


  2 in total

1.  A Review of Mine Rescue Ensembles for Underground Coal Mining in the United States.

Authors:  F Selcen Kilinc; William D Monaghan; Jeffrey B Powell
Journal:  J Eng Fiber Fabr       Date:  2014       Impact factor: 1.573

2.  The Effect of Various Hot Environments on Physiological Responses and Information Processing Performance Following Firefighting Activities in a Smoke-Diving Room.

Authors:  Rasoul Hemmatjo; Majid Motamedzade; Mohsen Aliabadi; Omid Kalatpour; Maryam Farhadian
Journal:  Saf Health Work       Date:  2017-02-27
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.