Literature DB >> 21150762

Accuracy of free-hand pedicle screws in the thoracic and lumbar spine: analysis of 6816 consecutive screws.

Scott L Parker1, Matthew J McGirt, S Harrison Farber, Anubhav G Amin, Anne-Marie Rick, Ian Suk, Ali Bydon, Daniel M Sciubba, Jean-Paul Wolinsky, Ziya L Gokaslan, Timothy F Witham.   

Abstract

BACKGROUND: Pedicle screws are used to stabilize all 3 columns of the spine, but can be technically demanding to place. Although intraoperative fluoroscopy and stereotactic-guided techniques slightly increase placement accuracy, they are also associated with increased radiation exposure to patient and surgeon as well as increased operative time.
OBJECTIVE: To describe and critically evaluate our 7-year institutional experience with placement of pedicle screws in the thoracic and lumbar spine using a free-hand technique.
METHODS: We retrospectively reviewed records of all patients undergoing free-hand pedicle screw placement without fluoroscopy in the thoracic or lumbar spine between June 2002 and June 2009. Incidence and extent of cortical breach by misplaced pedicle screw was determined by review of postoperative computed tomography scans. We defined breach as more than 25% of the screw diameter residing outside of the pedicle or vertebral body cortex.
RESULTS: A total of 964 patients received 6816 free-hand placed pedicle screws in the thoracic or lumbar spine. Indications for hardware placement were degenerative/deformity disease (51.2%), spondylolisthesis (23.7%), tumor (22.7%), trauma (11.3%), infection (7.6%), and congenital (0.9%). A total of 115 screws (1.7%) were identified as breaching the pedicle in 87 patients (9.0%). Breach occurred more frequently in the thoracic than the lumbar spine (2.5% and 0.9%, respectively; P < .0001) and was more often lateral (61.3%) than medial (32.8%) or superior (2.5%). T4 (4.1%) and T6 (4.0%) experienced the highest breach rate, whereas L5 and S1 had the lowest breach rate. Eight patients (0.8%) underwent revision surgery to correct malpositioned screws.
CONCLUSION: Free-hand pedicle screw placement based on external anatomy alone can be performed with acceptable safety and accuracy and allows avoidance of radiation exposure encountered in fluoroscopic techniques. Image-guided assistance may be most valuable when placing screws between T4 and T6, where breach rates are highest.

Entities:  

Mesh:

Year:  2011        PMID: 21150762     DOI: 10.1227/NEU.0b013e3181fdfaf4

Source DB:  PubMed          Journal:  Neurosurgery        ISSN: 0148-396X            Impact factor:   4.654


  59 in total

1.  Fluoroscopy-guided pedicle screw accuracy with a mini-open approach: a tomographic evaluation of 470 screws in 125 patients.

Authors:  José Antonio Soriano-Sánchez; Luis Alberto Ortega-Porcayo; Carlos Francisco Gutiérrez-Partida; Luis Rodolfo Ramírez-Barrios; Ramses Uriel Ortíz-Leyva; Manuel Rodríguez-García; Oscar Sánchez-Escandón
Journal:  Int J Spine Surg       Date:  2015-10-23

2.  Pedicle screw insertion accuracy in terms of breach and reposition using a new intraoperative cone beam computed tomography imaging technique and evaluation of the factors associated with these parameters of accuracy: a series of 695 screws.

Authors:  Virginie Cordemans; Ludovic Kaminski; Xavier Banse; Bernard G Francq; Christine Detrembleur; Olivier Cartiaux
Journal:  Eur Spine J       Date:  2017-06-19       Impact factor: 3.134

3.  Radiation dose reduction in thoracic and lumbar spine instrumentation using navigation based on an intraoperative cone beam CT imaging system: a prospective randomized clinical trial.

Authors:  Nathalie Pireau; Virginie Cordemans; Xavier Banse; Nadia Irda; Sébastien Lichtherte; Ludovic Kaminski
Journal:  Eur Spine J       Date:  2017-07-22       Impact factor: 3.134

4.  Technical Report of Free Hand Pedicle Screw Placement using the Entry Points with Junction of Proximal Edge of Transverse Process and Lamina in Lumbar Spine: Analysis of 2601 Consecutive Screws.

Authors:  Chang Hyun Oh; Seung Hwan Yoon; Yongjung J Kim; Dongkeun Hyun; Hyeong-Chun Park
Journal:  Korean J Spine       Date:  2013-03-31

Review 5.  The evolution of image-guided lumbosacral spine surgery.

Authors:  Austin C Bourgeois; Austin R Faulkner; Alexander S Pasciak; Yong C Bradley
Journal:  Ann Transl Med       Date:  2015-04

6.  Reduction in complication and revision rates for robotic-guided short-segment lumbar fusion surgery: results of a prospective, multi-center study.

Authors:  Jason I Liounakos; Vignessh Kumar; Aria Jamshidi; Zmira Silman; Christopher R Good; Samuel R Schroerlucke; Andrew Cannestra; Victor Hsu; Jae Lim; Faissal Zahrawi; Pedro M Ramirez; Thomas M Sweeney; Michael Y Wang
Journal:  J Robot Surg       Date:  2021-01-01

Review 7.  Pedicle screw insertion techniques: an update and review of the literature.

Authors:  F Perna; R Borghi; F Pilla; N Stefanini; A Mazzotti; M Chehrassan
Journal:  Musculoskelet Surg       Date:  2016-11-19

8.  Reliability of the Planned Pedicle Screw Trajectory versus the Actual Pedicle Screw Trajectory using Intra-operative 3D CT and Image Guidance.

Authors:  Catherine A Miller; Charles G Ledonio; Matthew A Hunt; Farhan Siddiq; David W Polly
Journal:  Int J Spine Surg       Date:  2016-10-24

9.  [Importance of intraoperative navigation in spinal surgery].

Authors:  P H Richter; F Gebhard; M Kraus
Journal:  Chirurg       Date:  2014-10       Impact factor: 0.955

Review 10.  Techniques and accuracy of thoracolumbar pedicle screw placement.

Authors:  Varun Puvanesarajah; Jason A Liauw; Sheng-Fu Lo; Ioan A Lina; Timothy F Witham
Journal:  World J Orthop       Date:  2014-04-18
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.