A history of intraocular pressure and its measurement.

Robert L Stamper1.   

Abstract

Doctors have not always associated elevated intraocular pressure with the vision loss from glaucoma. Although several individuals appear to have noted firmness of the eye in this condition as far back as the 10th century, elevated intraocular pressure was not routinely assessed until the latter part of the 19th century. von Graefe developed the first instrument for measuring intraocular pressure in 1865. The first reasonably accurate instrument was the Maklakoff applanation tonometer of the late 19th century; it was in widespread use throughout Eastern Europe until relatively recently. Schiötz developed an indentation tonometer that was widely used throughout the world during the first two thirds of the 20th century. Goldmann's applanation tonometer of 1950 began the era of truly accurate intraocular pressure measurement. It is still the most widely used tonometer in the world. Other devices such as the McKay-Marg tonometer (or its offspring the Tono-Pen), the pneumatonometer, and airpuff applanation tonometers are gaining adherents. The dynamic contour tonometer is the first totally new concept in tonometry in over 100 years. It is probably the most accurate of all the tonometers and is relatively independent of corneal biomechanical properties unlike its predecessors. Transpalpebral tonometers are attractive as they do not require topical anesthesia; however, they add the biomechanical properties of the eyelid to the list of potential errors and have not proven very accurate. The future should, hopefully, bring tonometers that can give diurnal or even longer indications of intraocular pressure variation. Although intraocular pressure elevation (or its absence) no longer can be counted on for diagnostic purposes, the role of intraocular pressure in the management of glaucomatous optic neuropathy remains critical.

Entities:  

Mesh:

Year:  2011        PMID: 21150677     DOI: 10.1097/OPX.0b013e318205a4e7

Source DB:  PubMed          Journal:  Optom Vis Sci        ISSN: 1040-5488            Impact factor:   1.973


  20 in total

1.  Agreement among Goldmann applanation tonometer, iCare, and Icare PRO rebound tonometers; non-contact tonometer; and Tonopen XL in healthy elderly subjects.

Authors:  Yoshitake Kato; Shunsuke Nakakura; Naoko Matsuo; Kayo Yoshitomi; Marina Handa; Hitoshi Tabuchi; Yoshiaki Kiuchi
Journal:  Int Ophthalmol       Date:  2017-04-09       Impact factor: 2.031

2.  Intraocular Pressure Changes Following Intravitreal Melphalan and Topotecan for the Treatment of Retinoblastoma With Vitreous Seeding.

Authors:  Matthew D Karl; Jasmine H Francis; Saipriya Iyer; Brian Marr; David H Abramson
Journal:  J Pediatr Ophthalmol Strabismus       Date:  2017-01-17       Impact factor: 1.402

Review 3.  Tonometers-which one should I use?

Authors:  Kanza Aziz; David S Friedman
Journal:  Eye (Lond)       Date:  2018-02-19       Impact factor: 3.775

4.  Posner-Schlossman syndrome induced laser in situ keratomileusis keratectasia-a case report.

Authors:  Xiu Wang; Elizabeth Wl Lim; Li Lim; Rui-Hua Wei
Journal:  Int J Ophthalmol       Date:  2017-10-18       Impact factor: 1.779

5.  Finite element method for estimation of applanation force and to study the influence of intraocular pressure of eye on tonometry.

Authors:  R B Bharathi; Rakshath G Poojary; Gopalakrishna K Prabhu; Ramesh S Ve
Journal:  Int Ophthalmol       Date:  2022-06-04       Impact factor: 2.029

6.  Comparison of intraocular pressure measurements with different contact tonometers in young healthy persons.

Authors:  Saulius Galgauskas; Rasa Strupaite; Ernesta Strelkauskaite; Rimvydas Asoklis
Journal:  Int J Ophthalmol       Date:  2016-01-18       Impact factor: 1.779

7.  An innovative educational model in intraocular pressure measurement.

Authors:  Roghayeh Heidary; Fatemeh Heidary; Abolfazl Rahimi; Reza Gharebaghi
Journal:  Med Hypothesis Discov Innov Ophthalmol       Date:  2012

8.  Detecting IOP Fluctuations in Glaucoma Patients.

Authors:  Brenda Nuyen; Kaweh Mansouri
Journal:  Open Ophthalmol J       Date:  2016-02-29

9.  Comparison of three methods of tonometry in normal subjects: Goldmann applanation tonometer, non-contact airpuff tonometer, and Tono-Pen XL.

Authors:  Ihsan Yilmaz; Cigdem Altan; Ebru Demet Aygit; Cengiz Alagoz; Okkes Baz; Sibel Ahmet; Semih Urvasizoglu; Dilek Yasa; Ahmet Demirok
Journal:  Clin Ophthalmol       Date:  2014-06-07

Review 10.  Tonometry and Care of Tonometers.

Authors:  Rajat Maheshwari; Nikhil S Choudhari; Manav Deep Singh
Journal:  J Curr Glaucoma Pract       Date:  2012-10-16
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.