Literature DB >> 21147788

Deriving staff and public doses in a PET/CT facility from measured radiation levels using thermoluminescent dosimetry.

Abdalla N Al-Haj1, Aida M Lobriguito, Ahnaf Arafah, Ruchana Parker.   

Abstract

The introduction of PET/CT at King Faisal Specialist Hospital and Research Centre for whole body and brain imaging has become favourable for diagnosis of cancer. There is no data available on the PET/CT dose to staff and members of the public for different activities of (18)F [fluorodeoxyglucose (FDG)] and for longer patient holding time. The study aims to determine and evaluate staff and public doses by using thermoluminescent dosemeters monthly readings for a 7-month deployment period and by using direct measurements of dose rates at 30 cm and 1 m distances from the patients after injection. The whole body doses per procedure and per administered activity of (18)F (FDG) were estimated. A dose map inside the PET/CT was generated to provide information of the dose levels in different locations. The Pearson correlation showed a strong correlation (r(2) = 0.71) between the dose per activity and the number of patients. Optimisation of radiation protection of staff and members of the public was investigated and recommendations were given.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 21147788     DOI: 10.1093/rpd/ncq452

Source DB:  PubMed          Journal:  Radiat Prot Dosimetry        ISSN: 0144-8420            Impact factor:   0.972


  5 in total

1.  Exposure Doses to Technologists Working in 7 PET/CT Departments.

Authors:  Weiguo Li; Lianying Fang; Jieqing Li
Journal:  Dose Response       Date:  2020-07-09       Impact factor: 2.658

2.  Effective dose to staff members in a positron emission tomography/CT facility using zirconium-89.

Authors:  K S Alzimami; A K Ma
Journal:  Br J Radiol       Date:  2013-08-09       Impact factor: 3.039

3.  Dosimetry of patients submitted to cerebral PET/CT for the diagnosis of mild cognitive impairment.

Authors:  Priscila do Carmo Santana; Arnaldo Prata Mourão; Paulo Márcio Campos de Oliveira; Felipe Dias Bernardes; Marcelo Mamede; Teógenes Augusto da Silva
Journal:  Radiol Bras       Date:  2014 Nov-Dec

4.  Evaluation of Radiation Exposure to Staff and Environment Dose from [18F]-FDG in PET/CT and Cyclotron Center using Thermoluminescent Dosimetry.

Authors:  S Zargan; P Ghafarian; A Shabestani Monfared; A A Sharafi; M Bakhshayeshkaram; M R Ay
Journal:  J Biomed Phys Eng       Date:  2017-03-01

5.  Investigation of 18F and 89Zr Isotopes Self-Absorption and Dose Rate Parameters for PET Imaging.

Authors:  Abdulrahman A Alfuraih; Khalid Alzimami; Andy K Ma
Journal:  Dose Response       Date:  2021-07-09       Impact factor: 2.658

  5 in total