Literature DB >> 21146370

Seizure detection using digital trend analysis: Factors affecting utility.

Cigdem I Akman1, Vesna Micic, Anita Thompson, James J Riviello.   

Abstract

BACKGROUND: EEG monitoring is important for the early detection of seizures during the course of critical illness. However, the logistics of real time EEG interpretation is challenging for the neurophysiology and critical care medicine teams. This study evaluated factors affecting the utility of digital trend analysis (DTA) for rapid seizure identification in children.
METHODS: digital EEG files of seizures in critically ill children were retrieved for DTA. The envelop trend (ET) and compressed spectral array (CSA) were applied to the raw EEG data and presented to an experienced and inexperienced user for interpretation who were blinded to conventional EEG findings. The EEG findings with and without presence of seizures and features of seizures were analyzed.
RESULTS: we found that a number of factors affected accurate seizure detection including factors related to interpreter's experiences, display size and type of DTA methods used for analysis in addition to baseline EEG findings. ET was more dependent on user experience, furthermore, display size and multimodal DTA application (CSA and ET combined) increased the sensitivity of seizure detection for the experienced user compared to inexperience users. The artifacts were reported as seizures regardless of experience without presence of conventional EEG recording. The maximum spike amplitude, seizure duration, and seizure frequency were other important determinants for accuracy. Electrographic seizures with shorter duration were better detected by ET, and the maximum spike amplitude was important for both the ET and CSA. Repetitive seizures are readily detected by both digital trending methods. Artifacts may be reported as seizures regardless of experience if conventional EEG recording is not available for the interpretation.
CONCLUSION: DTA applied to the raw EEG data does produce a graphic display that facilitates identification of seizures. The actual characteristics of the electrographic seizure may predict which DTA method is better and the overall accuracy of seizure detection may increase when multimodal trending is used simultaneously. Application of DTA alone with display of conventional EEG is beneficial for rapid interpretation of EEG findings regardless of experience. 2010 Elsevier B.V. All rights reserved.

Entities:  

Mesh:

Year:  2010        PMID: 21146370     DOI: 10.1016/j.eplepsyres.2010.10.018

Source DB:  PubMed          Journal:  Epilepsy Res        ISSN: 0920-1211            Impact factor:   3.045


  14 in total

Review 1.  Continuous EEG monitoring in the intensive care unit.

Authors:  Jeffrey D Kennedy; Elizabeth E Gerard
Journal:  Curr Neurol Neurosci Rep       Date:  2012-08       Impact factor: 5.081

2.  Guiding Principles for a Pediatric Neurology ICU (neuroPICU) Bedside Multimodal Monitor: Findings from an International Working Group.

Authors:  Zachary M Grinspan; Yonina C Eldar; Daniel Gopher; Amihai Gottlieb; Rotem Lammfromm; Halinder S Mangat; Nimrod Peleg; Steven Pon; Igal Rozenberg; Nicholas D Schiff; David E Stark; Peter Yan; Hillel Pratt; Barry E Kosofsky
Journal:  Appl Clin Inform       Date:  2016-05-18       Impact factor: 2.342

3.  Single-channel amplitude integrated EEG recording for the identification of epileptic seizures by nonexpert physicians in the adult acute care setting.

Authors:  Rainer Nitzschke; Jakob Müller; Ria Engelhardt; Gunter N Schmidt
Journal:  J Clin Monit Comput       Date:  2011-10-19       Impact factor: 2.502

4.  cEEG electrode-related pressure ulcers in acutely hospitalized patients.

Authors:  Lidia M V R Moura; Thiago S Carneiro; David Kwasnik; Valdery F Moura; Christine S Blodgett; Joseph Cohen; Mary McKenna Guanci; Daniel B Hoch; John Hsu; Andrew J Cole; M Brandon Westover
Journal:  Neurol Clin Pract       Date:  2017-02

5.  Quantitative EEG is an objective, sensitive, and reliable indicator of transient anesthetic effects during Wada tests.

Authors:  Bin Tu; Nadege J Assassi; Carl W Bazil; Marla J Hamberger; Lawrence J Hirsch
Journal:  J Clin Neurophysiol       Date:  2015-04       Impact factor: 2.177

Review 6.  Electroencephalography in epilepsy: look for what could be beyond the visual inspection.

Authors:  Boulenouar Mesraoua; Dirk Deleu; Hassan Al Hail; Gayane Melikyan; Paul Boon; Hiba A Haider; Ali A Asadi-Pooya
Journal:  Neurol Sci       Date:  2019-07-27       Impact factor: 3.307

Review 7.  Pediatric ICU EEG monitoring: current resources and practice in the United States and Canada.

Authors:  Sarah M Sanchez; Jessica Carpenter; Kevin E Chapman; Dennis J Dlugos; William B Gallentine; Christopher C Giza; Joshua L Goldstein; Cecil D Hahn; Sudha K Kessler; Tobias Loddenkemper; James J Riviello; Nicholas S Abend
Journal:  J Clin Neurophysiol       Date:  2013-04       Impact factor: 2.177

8.  Electrographic seizures in pediatric ICU patients: cohort study of risk factors and mortality.

Authors:  Nicholas S Abend; Daniel H Arndt; Jessica L Carpenter; Kevin E Chapman; Karen M Cornett; William B Gallentine; Christopher C Giza; Joshua L Goldstein; Cecil D Hahn; Jason T Lerner; Tobias Loddenkemper; Joyce H Matsumoto; Kristin McBain; Kendall B Nash; Eric Payne; Sarah M Sánchez; Iván Sánchez Fernández; Justine Shults; Korwyn Williams; Amy Yang; Dennis J Dlugos
Journal:  Neurology       Date:  2013-06-21       Impact factor: 9.910

9.  Sensitivity of quantitative EEG for seizure identification in the intensive care unit.

Authors:  Hiba A Haider; Rosana Esteller; Cecil D Hahn; M Brandon Westover; Jonathan J Halford; Jong W Lee; Mouhsin M Shafi; Nicolas Gaspard; Susan T Herman; Elizabeth E Gerard; Lawrence J Hirsch; Joshua A Ehrenberg; Suzette M LaRoche
Journal:  Neurology       Date:  2016-07-27       Impact factor: 9.910

Review 10.  Electroencephalographic monitoring in the pediatric intensive care unit.

Authors:  Nicholas S Abend; Kevin E Chapman; William B Gallentine; Joshua Goldstein; Ann E Hyslop; Tobias Loddenkemper; Kendall B Nash; James J Riviello; Cecil D Hahn
Journal:  Curr Neurol Neurosci Rep       Date:  2013-03       Impact factor: 5.081

View more