Verification bias an underrecognized source of error in assessing the efficacy of medical imaging.

Jonelle M Petscavage1, Michael L Richardson, Robert B Carr.   

Abstract

RATIONALE AND
OBJECTIVES: Diagnostic tests are validated by comparison against a "gold standard" reference test. When the reference test is invasive or expensive, it may not be applied to all patients. This can result in biased estimates of the sensitivity and specificity of the diagnostic test. This type of bias is called "verification bias," and is a common problem in imaging research. The purpose of our study is to estimate the prevalence of verification bias in the recent radiology literature.
MATERIALS AND METHODS: All issues of the American Journal of Roentgenology (AJR), Academic Radiology, Radiology, and European Journal of Radiology (EJR) between November 2006 and October 2009 were reviewed for original research articles mentioning sensitivity or specificity as endpoints. Articles were read to determine whether verification bias was present and searched for author recognition of verification bias in the design.
RESULTS: During 3 years, these journals published 2969 original research articles. A total of 776 articles used sensitivity or specificity as an outcome. Of these, 211 articles demonstrated potential verification bias. The fraction of articles with potential bias was respectively 36.4%, 23.4%, 29.5%, and 13.4% for AJR, Academic Radiology, Radiology, and EJR. The total fraction of papers with potential bias in which the authors acknowledged this bias was 17.1%.
CONCLUSION: Verification bias is a common and frequently unacknowledged source of error in efficacy studies of diagnostic imaging. Bias can often be eliminated by proper study design. When it cannot be eliminated, it should be estimated and acknowledged. Published by Elsevier Inc.

Entities:  

Mesh:

Year:  2010        PMID: 21145764     DOI: 10.1016/j.acra.2010.10.005

Source DB:  PubMed          Journal:  Acad Radiol        ISSN: 1076-6332            Impact factor:   3.173


  5 in total

1.  Detection of noncalcified pulmonary nodules on low-dose MDCT: comparison of the sensitivity of two CAD systems by using a double reference standard.

Authors:  A R Larici; M Amato; P Ordóñez; F Maggi; L Menchini; A Caulo; L Calandriello; G Vallati; S Giunta; M Crecco; L Bonomo
Journal:  Radiol Med       Date:  2012-02-10       Impact factor: 3.469

Review 2.  [Systematic errors in clinical studies : A comprehensive survey].

Authors:  W A Golder
Journal:  Ophthalmologe       Date:  2017-03       Impact factor: 1.059

Review 3.  [Systematic errors in clinical studies : A comprehensive survey].

Authors:  W A Golder
Journal:  Z Rheumatol       Date:  2017-02       Impact factor: 1.372

4.  Imaging of the post-operative shoulder: does injection of iodinated contrast in addition to MR contrast during arthrography improve diagnostic accuracy and patient throughput?

Authors:  Thomas Magee
Journal:  Skeletal Radiol       Date:  2018-03-17       Impact factor: 2.199

5.  Accuracy of Two-Dimensional Transvaginal Sonography and Office Hysteroscopy for Detection of Uterine Abnormalities in Patients with Repeated Implantation Failures or Recurrent Pregnancy Loss.

Authors:  Marzieh Shiva; Firouzeh Ahmadi; Arezoo Arabipoor; Mansoureh Oromiehchi; Mohammad Chehrazi
Journal:  Int J Fertil Steril       Date:  2017-10-12
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.