This paper provides an evaluation of a fractional order model for the respiratory input impedance, using two groups of subjects, respectively healthy and asthmatic children. The purpose is to verify if the model is able to deliver statistically meaningful parameter values in order to classify the two groups. The data are gathered with the non-invasive lung function test of forced oscillations technique, by means of a multisine signal within the 4-48Hz frequency range. Based on our previous work, a fractional order model for this range of frequencies is obtained. Additional parameters are proposed to evaluate the two groups. The results indicate that the model was unable to detect significant changes between the asthmatic children with normal spirometry results (as result of medication) and the healthy children. Due to medication intake during the hours prior to the exam, bronchial challenge did not modify substantially the respiratory parameters. Our findings correspond to similar studies reported in the specialized literature. Combined model parameters, such as the tissue damping and the tissue elastance were significantly different in the two groups (p<0.01). Two extra indexes are introduced: the quality factor and the power factor, providing significantly different results between the two groups (p≪0.01). We conclude that the model can be used in the respective frequency range to characterize the two groups efficiently.
Copyright © 2010 Elsevier Ireland Ltd. All rights reserved.

Entities:  

Mesh:

Year:  2010        PMID: 21145613     DOI: 10.1016/j.cmpb.2010.11.010

Source DB:  PubMed          Journal:  Comput Methods Programs Biomed        ISSN: 0169-2607            Impact factor:   5.428


  5 in total

1.  Oscillation Mechanics, Integer and Fractional Respiratory Modeling in COPD: Effect of Obstruction Severity.

Authors:  Caroline Oliveira Ribeiro; Agnaldo José Lopes; Pedro Lopes de Melo
Journal:  Int J Chron Obstruct Pulmon Dis       Date:  2020-12-08

2.  Respiratory resistance and reactance in adults with sickle cell anemia: Part 2-Fractional-order modeling and a clinical decision support system for the diagnosis of respiratory disorders.

Authors:  Cirlene de Lima Marinho; Maria Christina Paixão Maioli; Jorge Luis Machado do Amaral; Agnaldo José Lopes; Pedro Lopes de Melo
Journal:  PLoS One       Date:  2019-03-07       Impact factor: 3.240

3.  Combined forced oscillation and fractional-order modeling in patients with work-related asthma: a case-control study analyzing respiratory biomechanics and diagnostic accuracy.

Authors:  Fábio Augusto D Alegria Tuza; Paula Morisco de Sá; Hermano A Castro; Agnaldo José Lopes; Pedro Lopes de Melo
Journal:  Biomed Eng Online       Date:  2020-12-09       Impact factor: 2.819

4.  Early Diagnosis of Respiratory Abnormalities in Asbestos-Exposed Workers by the Forced Oscillation Technique.

Authors:  Paula Morisco de Sá; Hermano Albuquerque Castro; Agnaldo José Lopes; Pedro Lopes de Melo
Journal:  PLoS One       Date:  2016-09-09       Impact factor: 3.240

5.  Forced oscillation technique for early detection of the effects of smoking and COPD: contribution of fractional-order modeling.

Authors:  Caroline Oliveira Ribeiro; Alvaro Camilo Dias Faria; Agnaldo José Lopes; Pedro Lopes de Melo
Journal:  Int J Chron Obstruct Pulmon Dis       Date:  2018-10-11