Literature DB >> 21144690

Favorable outcomes with in situ techniques for surgical repair of complex renal artery aneurysms.

William P Robinson1, Richard Bafford, Michael Belkin, Matthew T Menard.   

Abstract

OBJECTIVE: The optimal method of operative management of complex branch renal artery aneurysms (RAAs) remains unclear, with recent reports predominantly espousing endovascular and ex vivo repair. We sought to determine the long-term outcome of RAA repair performed with autogenous in situ techniques.
METHODS: This was a cohort study of patients undergoing surgical repair of RAAs identified from our prospective vascular division registry (1984-2009).
RESULTS: Twenty-six RAAs were repaired in 24 patients (17 women, 7 men; mean age, 52 ± 16 years). Mean size was 2.3 ± 0.7 cm (range, 0.7-4.0 cm). Twenty RAAs were repaired based on size and six for hypertension alone. Multiple RAAs were present in 13 patients (54%). Associated conditions included hypertension in 24 (100%), fibromuscular dysplasia in 6 (25%), coexistent renal artery stenosis in 6 (25%), and aortic aneurysm in 3 (12.5%). Reconstruction of first- or second-order branches was required in 25 RAAs (96%). In situ techniques were used in 22 repairs and included resection combined with autogenous vein bypass and interposition in 11, primary anastomosis to conjoined outflow vessels in 3, and aortic reimplantation in 2. Aneurysmorrhaphy was combined with vein patch angioplasty in 6, exclusion in 2, tailored primary closure in 1, and autogenous bypass in 1. Four patients underwent ex vivo reconstruction. Perioperative mortality was 0% and morbidity was 11.5%, including one nephrectomy during ex vivo repair for immediate thrombosis. Renal function was preserved (preoperative creatinine, 0.94 ± 0.3 vs postoperative creatinine 1.06 ± 0.4 mg/dL; P = .11). Systolic (SBP) and diastolic blood pressure (DBP) control improved after operation: preoperative SBP 142 ± 18 vs postoperative SBP 130 ± 15 mm Hg (P = .007) and preoperative DBP 86 ± 14 vs postoperative DBP 78 ± 10 mm Hg (P = .01). Long-term patency was evaluated in 18 reconstructions (69%) by duplex imaging or contrast radiography at an average long-term follow-up of 99 months (range, 1-300 months) and was 94%. Five-year freedom from rupture and survival by the Kaplan-Meier method was 100%.
CONCLUSION: In situ techniques allow repair of complex RAAs involving branch vessels with minimal morbidity, improved blood pressure control, and maintenance of renal function. This operative approach further provides excellent long-term patency and survival in this relatively young patient population.
Copyright © 2011 Society for Vascular Surgery. Published by Mosby, Inc. All rights reserved.

Entities:  

Mesh:

Year:  2010        PMID: 21144690     DOI: 10.1016/j.jvs.2010.10.050

Source DB:  PubMed          Journal:  J Vasc Surg        ISSN: 0741-5214            Impact factor:   4.268


  11 in total

1.  Surgical repair of renal artery aneurysms.

Authors:  Nicole Titze; Victoria Ivanukoff; Tammy Fisher; Gregory Pearl; Brad Grimsley; William P Shutze
Journal:  Proc (Bayl Univ Med Cent)       Date:  2015-10

2.  Repair of renal artery aneurysm with stent angiography and coil embolization.

Authors:  Lauren Dinh; Mohanad Hamandi; William Shutze
Journal:  Proc (Bayl Univ Med Cent)       Date:  2021-01-11

3.  Management and outcomes of isolated renal artery aneurysms in the endovascular era.

Authors:  Dominique B Buck; Thomas Curran; John C McCallum; Jeremy Darling; Rishi Mamtani; Joost A van Herwaarden; Frans L Moll; Marc L Schermerhorn
Journal:  J Vasc Surg       Date:  2015-09-18       Impact factor: 4.268

Review 4.  Renal artery aneurysms.

Authors:  J González; M Esteban; G Andrés; E Linares; J I Martínez-Salamanca
Journal:  Curr Urol Rep       Date:  2014-01       Impact factor: 3.092

5.  Role of heterotopic kidney auto-transplantation for renal artery aneurysms.

Authors:  Jun G Gwon; Duck J Han; Yong-Pil Cho; Young H Kim; Tae-Won Kwon
Journal:  Medicine (Baltimore)       Date:  2018-06       Impact factor: 1.889

6.  Orthotopic renal autotransplantation for young-onset and medical treatment-requiring complex renovascular hypertension.

Authors:  Fang-Da Li; Zhi-Gang Ji; Chang-Wei Liu; Jiang Shao; Yi Xie; Yue-Hong Zheng
Journal:  J Renin Angiotensin Aldosterone Syst       Date:  2018 Jul-Sep       Impact factor: 1.636

7.  Packing Technique with or without Remodeling for Endovascular Coil Embolization of Renal Artery Aneurysms: Safety, Efficacy and Mid-Term Outcomes.

Authors:  Grégory Secco; Olivier Chevallier; Nicolas Falvo; Kévin Guillen; Pierre-Olivier Comby; Christiane Mousson; Nabil Majbri; Marco Midulla; Romaric Loffroy
Journal:  J Clin Med       Date:  2021-01-17       Impact factor: 4.241

8.  Results of Surgical Repair of Hilar Renal Artery Aneurysm to Preserve Renal Blood Flow.

Authors:  Takumi Kawase; Yosuke Inoue; Jiro Matsuo; Atsushi Omura; Yoshimasa Seike; Kyokun Uehara; Hiroaki Sasaki; Hitoshi Matsuda
Journal:  Ann Vasc Dis       Date:  2020-09-25

9.  Vascular fluorescence imaging control for complex renal artery aneurysm repair using laparoscopic nephrectomy and autotransplantation.

Authors:  Matteo Tozzi; Luigi Boni; Gabriele Soldini; Marco Franchin; Gabriele Piffaretti
Journal:  Case Rep Transplant       Date:  2014-08-10

10.  Endovascular management of renal artery aneurysms using the multilayer flow modulator.

Authors:  Sherif Sultan; Mahmoud Basuoniy Alawy; Rita Flaherty; Edel P Kavanagh; Mohamed Elsherif; Ala Elhelali; Florian Stefanov; Violet Lundon; Niamh Hynes
Journal:  Open Heart       Date:  2016-03-10
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.