Literature DB >> 21142787

The effect of different surface treatments on cement-retained implant-supported restorations.

Murat Kurt1, Tolga Külünk, Cağrı Ural, Şafak Külünk, Şengül Danişman, Soner Savaş.   

Abstract

The purpose of this study was to evaluate the effects of the various surface treatment methods on the retention of single crowns on implant abutments. The study included 50 single crowns that were cemented with adhesive resin cement onto the ITI solid abutments. The specimens were randomly divided into 5 groups, each including 10 specimens according to the following surface treatments: group C, control, abutments remained unaltered as control; group L, etching with CO(2) laser; group SB, sandblasting with 50-μm Al(2)O(3); group MS: coating with titanium nitride (TiAlN) with a radiofrequency magnetron sputtering system; and group SP, silicoating by Silano-Pen. After the surface treatment procedures were finished, the casted crowns were cemented onto the abutments, and thermocycling was applied to simulate oral environment. The uniaxial tensile force was applied to all test crowns using a universal test machine (Instron) with a crosshead speed of 0.5 mm/min. The load required to dislodge each crown was recorded in Newton. The lowest tensile bond strength values were obtained with group MS (223.26 ± 14.30 N) and significantly differ from all other groups except group C. Group SB showed highest test results (506.02 ± 18.04 N) and differs from other groups (P < .05). The test values that were obtained in group MS-group C did not show significant differences (P > .05). Sandblasting is an effective method to increase bond strength. Also, Silano-Pen and laser application is advisable for increasing the crown retention to abutments. Titanium aluminum nitride coating with magnetron sputtering technique seems to be ineffective.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 21142787     DOI: 10.1563/AAID-JOI-D-10-00151

Source DB:  PubMed          Journal:  J Oral Implantol        ISSN: 0160-6972            Impact factor:   1.779


  2 in total

1.  The effect of ultrafast fiber laser application on the bond strength of resin cement to titanium.

Authors:  Sabit Melih Ates; Fatih Mehmet Korkmaz; Ipek Satıroglu Caglar; Zeynep Yeşil Duymus; Sedanur Turgut; Elif Arslan Bagis
Journal:  Lasers Med Sci       Date:  2017-05-02       Impact factor: 3.161

2.  Retention of different temporary cements tested on zirconia crowns and titanium abutments in vitro.

Authors:  Felix Dähne; Heike Meißner; Klaus Böning; Christin Arnold; Ralf Gutwald; Elisabeth Prause
Journal:  Int J Implant Dent       Date:  2021-07-20
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.