Literature DB >> 21142329

Knee joint secondary motion accuracy improved by quaternion-based optimizer with bony landmark constraints.

Hongsheng Wang1, Naiqaun Nigel Zheng.   

Abstract

Skin marker-based motion analysis has been widely used in biomechanical studies and clinical applications. Unfortunately, the accuracy of knee joint secondary motions is largely limited by the nonrigidity nature of human body segments. Numerous studies have investigated the characteristics of soft tissue movement. Utilizing these characteristics, we may improve the accuracy of knee joint motion measurement. An optimizer was developed by incorporating the soft tissue movement patterns at special bony landmarks into constraint functions. Bony landmark constraints were assigned to the skin markers at femur epicondyles, tibial plateau edges, and tibial tuberosity in a motion analysis algorithm by limiting their allowed position space relative to the underlying bone. The rotation matrix was represented by quaternion, and the constrained optimization problem was solved by Fletcher's version of the Levenberg-Marquardt optimization technique. The algorithm was validated by using motion data from both skin-based markers and bone-mounted markers attached to fresh cadavers. By comparing the results with the ground truth bone motion generated from the bone-mounted markers, the new algorithm had a significantly higher accuracy (root-mean-square (RMS) error: 0.7 ± 0.1 deg in axial rotation and 0.4 ± 0.1 deg in varus-valgus) in estimating the knee joint secondary rotations than algorithms without bony landmark constraints (RMS error: 1.7 ± 0.4 deg in axial rotation and 0.7 ± 0.1 deg in varus-valgus). Also, it predicts a more accurate medial-lateral translation (RMS error: 0.4 ± 0.1 mm) than the conventional techniques (RMS error: 1.2 ± 0.2 mm). The new algorithm, using bony landmark constrains, estimates more accurate secondary rotations and medial-lateral translation of the underlying bone.

Entities:  

Mesh:

Year:  2010        PMID: 21142329     DOI: 10.1115/1.4002856

Source DB:  PubMed          Journal:  J Biomech Eng        ISSN: 0148-0731            Impact factor:   2.097


  3 in total

1.  Translation and rotation analysis based on stress MRI for the diagnosis of anterior cruciate ligament tears.

Authors:  Wojciech Klon; Marcin Domżalski; Konrad Malinowski; Bogusław Sadlik
Journal:  Quant Imaging Med Surg       Date:  2022-01

2.  Dynamic contact stress patterns on the tibial plateaus during simulated gait: a novel application of normalized cross correlation.

Authors:  Hongsheng Wang; Tony Chen; Peter Torzilli; Russell Warren; Suzanne Maher
Journal:  J Biomech       Date:  2013-12-03       Impact factor: 2.712

3.  Image based weighted center of proximity versus directly measured knee contact location during simulated gait.

Authors:  Hongsheng Wang; Tony Chen; Matthew F Koff; Ian D Hutchinson; Susannah Gilbert; Dan Choi; Russell F Warren; Scott A Rodeo; Suzanne A Maher
Journal:  J Biomech       Date:  2014-04-16       Impact factor: 2.712

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.