Literature DB >> 21140482

Liquid-based FNAC of the thyroid: a 4-year survey with SurePath.

Caroline Geers1, Claire Bourgain.   

Abstract

BACKGROUND: The aims of this study were to analyze cytomorphological features of Tripath PREP (BD SurePath, Burlington, NC) preparations in thyroid nodules and to examine adequacy and accuracy of SurePath and frozen sections for both clinical outcome and histological diagnosis when applicable.
METHODS: Gathered during a period of 4 years, 712 SurePath specimens of the thyroid were included. Histological (n = 207) or clinical follow-up (n = 505) was available in all cases. During the same period, 253 frozen sections of surgical thyroid resection specimens were also assessed. Sensitivity, specificity, accuracy, positive predictive value, and negative predictive value were calculated.
RESULTS: Sensitivity was 77% for SurePath and 29% for frozen section; specificity was 81% for SurePath and 100% for frozen section; accuracy was 80% for SurePath and 90% for frozen section. One hundred seventy-eight (25%) SurePath patients were considered unsatisfactory for diagnosis. In this study, sensitivity, specificity, and accuracy were comparable for SurePath and other reported results of liquid-based thyroid cytology. Presence of free colloid or pure cystic changes favored a benign diagnosis. Cellular smears with nuclear atypia of papillary carcinoma allowed an overt diagnosis of malignancy.
CONCLUSIONS: The authors concluded that SurePath is a reliable technique for assessment of thyroid nodules and offers the advantage of easy identification of colloid and atypical nuclei. Supplementary frozen section analysis should be limited to an FNAC diagnosis of suspicious for papillary carcinoma.
Copyright © 2010 American Cancer Society.

Entities:  

Mesh:

Year:  2010        PMID: 21140482     DOI: 10.1002/cncy.20125

Source DB:  PubMed          Journal:  Cancer Cytopathol        ISSN: 1934-662X            Impact factor:   5.284


  3 in total

1.  Application of liquid-based cytology to fine-needle aspiration biopsies of the thyroid gland.

Authors:  Esther Diana Rossi; Gian Franco Zannoni; Stefania Moncelsi; Egidio Stigliano; Giuseppe Santeusanio; Celestino Pio Lombardi; Alfredo Pontecorvi; Guido Fadda
Journal:  Front Endocrinol (Lausanne)       Date:  2012-05-16       Impact factor: 5.555

2.  Diagnostic value of liquid-based cytology with fine needle aspiration specimens for cervical lymphadenopathy.

Authors:  Nobuyuki Bandoh; Takashi Goto; Toshiaki Akahane; Natsumi Ohnuki; Tomomi Yamaguchi; Hajime Kamada; Yasuaki Harabuchi; Shinya Tanaka; Hiroshi Nishihara
Journal:  Diagn Cytopathol       Date:  2016-01-09       Impact factor: 1.582

3.  Can liquid-based preparation substitute for conventional smear in thyroid fine-needle aspiration? A systematic review based on meta-analysis.

Authors:  Yosep Chong; Soon-Jin Ji; Chang Suk Kang; Eun Jung Lee
Journal:  Endocr Connect       Date:  2017-10-10       Impact factor: 3.335

  3 in total