Literature DB >> 21134771

Gradient-induced longitudinal relaxation of hyperpolarized noble gases in the fringe fields of superconducting magnets used for magnetic resonance.

Wangzhi Zheng1, Zackary I Cleveland, Harald E Möller, Bastiaan Driehuys.   

Abstract

When hyperpolarized noble gases are brought into the bore of a superconducting magnet for magnetic resonance imaging (MRI) or spectroscopy studies, the gases must pass through substantial field gradients, which can cause rapid longitudinal relaxation. In this communication, we present a means of calculating this spatially dependent relaxation rate in the fringe field of typical magnets. We then compare these predictions to experimental measurements of (3)He relaxation at various positions near a medium-bore 2-T small animal MRI system. The calculated and measured relaxation rates on the central axis of the magnet agree well and show a maximum (3)He relaxation rate of 3.83×10(-3) s(-1) (T(1)=4.4 min) at a distance of 47 cm from the magnet isocenter. We also show that if this magnet were self-shielded, its minimum T(1) would drop to 1.2 min. In contrast, a typical self-shielded 1.5-T clinical MRI scanner will induce a minimum on-axis T(1) of 12 min. Additionally, we show that the cylindrically symmetric fields of these magnets enable gradient-induced relaxation to be calculated using only knowledge of the on-axis longitudinal field, which can either be measured directly or calculated from a simple field model. Thus, while most MRI magnets employ complex and proprietary current configurations, we show that their fringe fields and the resulting gradient-induced relaxation are well approximated by simple solenoid models. Finally, our modeling also demonstrates that relaxation rates can increase by nearly an order of magnitude at radial distances equivalent to the solenoid radius.
Copyright © 2010 Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 21134771      PMCID: PMC3026078          DOI: 10.1016/j.jmr.2010.11.006

Source DB:  PubMed          Journal:  J Magn Reson        ISSN: 1090-7807            Impact factor:   2.229


  15 in total

1.  129Xe-Xe molecular spin relaxation.

Authors:  B Chann; I A Nelson; L W Anderson; B Driehuys; T G Walker
Journal:  Phys Rev Lett       Date:  2002-02-28       Impact factor: 9.161

2.  Hybrid spin-exchange optical pumping of 3He.

Authors:  Earl Babcock; Ian Nelson; Steve Kadlecek; Bastiaan Driehuys; L W Anderson; F W Hersman; Thad G Walker
Journal:  Phys Rev Lett       Date:  2003-09-16       Impact factor: 9.161

3.  Limits to the polarization for spin-exchange optical pumping of 3He.

Authors:  E Babcock; B Chann; T G Walker; W C Chen; T R Gentile
Journal:  Phys Rev Lett       Date:  2006-03-03       Impact factor: 9.161

4.  Molecular imaging using a targeted magnetic resonance hyperpolarized biosensor.

Authors:  Leif Schröder; Thomas J Lowery; Christian Hilty; David E Wemmer; Alexander Pines
Journal:  Science       Date:  2006-10-20       Impact factor: 47.728

5.  Nuclear relaxation of 3He in the presence of O2.

Authors: 
Journal:  Phys Rev A       Date:  1995-07       Impact factor: 3.140

6.  Gaseous 3He-3He magnetic dipolar spin relaxation.

Authors: 
Journal:  Phys Rev A       Date:  1993-12       Impact factor: 3.140

7.  Brain MRI with laser-polarized 129Xe.

Authors:  S D Swanson; M S Rosen; B W Agranoff; K P Coulter; R C Welsh; T E Chupp
Journal:  Magn Reson Med       Date:  1997-11       Impact factor: 4.668

8.  Hyperpolarized 3-helium MR imaging of the lungs: testing the concept of a central production facility.

Authors:  E J R van Beek; J Schmiedeskamp; J M Wild; M N J Paley; F Filbir; S Fichele; F Knitz; G H Mills; N Woodhouse; A Swift; W Heil; M Wolf; E Otten
Journal:  Eur Radiol       Date:  2003-10-11       Impact factor: 5.315

9.  A robust protocol for regional evaluation of methacholine challenge in mouse models of allergic asthma using hyperpolarized 3He MRI.

Authors:  Abraham C Thomas; Erin N Potts; Ben T Chen; Deborah M Slipetz; W Michael Foster; Bastiaan Driehuys
Journal:  NMR Biomed       Date:  2009-06       Impact factor: 4.044

10.  Quantitative measurement of regional lung ventilation using 3He MRI.

Authors:  Anselm J Deninger; Sven Månsson; J Stefan Petersson; Göran Pettersson; Peter Magnusson; Jonas Svensson; Björn Fridlund; Georg Hansson; Ingrid Erjefeldt; Per Wollmer; Klaes Golman
Journal:  Magn Reson Med       Date:  2002-08       Impact factor: 4.668

View more
  7 in total

1.  Relaxation of hyperpolarized 129Xe in a deflating polymer bag.

Authors:  Harald E Möller; Zackary I Cleveland; Bastiaan Driehuys
Journal:  J Magn Reson       Date:  2011-06-25       Impact factor: 2.229

2.  Diffusion-mediated 129Xe gas depolarization in magnetic field gradients during continuous-flow optical pumping.

Authors:  Alex Burant; Rosa Tamara Branca
Journal:  J Magn Reson       Date:  2016-10-26       Impact factor: 2.229

3.  Optically polarized 3He.

Authors:  T R Gentile; P J Nacher; B Saam; T G Walker
Journal:  Rev Mod Phys       Date:  2017-12-11       Impact factor: 54.494

4.  A portable ventilator with integrated physiologic monitoring for hyperpolarized 129Xe MRI in rodents.

Authors:  Rohan S Virgincar; Jerry Dahlke; Scott H Robertson; Nathann Morand; Yi Qi; Simone Degan; Bastiaan Driehuys; John C Nouls
Journal:  J Magn Reson       Date:  2018-07-23       Impact factor: 2.229

5.  Preclinical hyperpolarized 129 Xe MRI: ventilation and T2 * mapping in mouse lungs at 7 T using multi-echo flyback UTE.

Authors:  Peter J Niedbalski; Alexander S Cochran; Teckla G Akinyi; Robert P Thomen; Elizabeth M Fugate; Diana M Lindquist; Ronald G Pratt; Zackary I Cleveland
Journal:  NMR Biomed       Date:  2020-04-14       Impact factor: 4.044

6.  In vivo MR imaging of pulmonary perfusion and gas exchange in rats via continuous extracorporeal infusion of hyperpolarized 129Xe.

Authors:  Zackary I Cleveland; Harald E Möller; Laurence W Hedlund; John C Nouls; Matthew S Freeman; Yi Qi; Bastiaan Driehuys
Journal:  PLoS One       Date:  2012-02-21       Impact factor: 3.240

7.  Continuous flow production of concentrated hyperpolarized xenon gas from a dilute xenon gas mixture by buffer gas condensation.

Authors:  Hirohiko Imai; Hironobu Yoshimura; Atsuomi Kimura; Hideaki Fujiwara
Journal:  Sci Rep       Date:  2017-08-04       Impact factor: 4.379

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.