Literature DB >> 21134614

Suture button compared with K-wire fixation for maintenance of posttrapeziectomy space height in a cadaver model of lateral pinch.

Jeffrey Yao1, Dan A Zlotolow, Ryan Murdock, Matthew Christian.   

Abstract

PURPOSE: Hematoma distraction arthroplasty has regained popularity as a treatment for thumb carpometacarpal arthritis with reports of satisfactory results. Our goal was to investigate the use of a suture button device to maintain the posttrapeziectomy space height of the thumb metacarpal. Our hypothesis is that a suture button that suspends the thumb metacarpal from the second metacarpal, when applied to the hematoma distraction arthroplasty technique, would provide subsidence resistance comparable to traditional K-wire fixation.
METHODS: Ten fresh frozen matched pairs of human cadaveric arms were used. After open trapeziectomy, suspension of the thumb metacarpal was performed with either a 1.4-mm (0.045-inch) K-wire advanced through the base of the thumb metacarpal into the second metacarpal shaft or a suture button device that suspended the thumb metacarpal from the second metacarpal shaft. Cyclic pinch was simulated by using a lateral pinch model previously described and validated. Lateral pinch is simulated by loading the extensor pollicis longus, adductor pollicis, abductor pollicis brevis, and flexor pollicis longus in a 1:5:6:10 ratio. Dynamic pinch is achieved with cyclic unloading of the abductor pollicis brevis, adductor pollicis, and flexor pollicis longus tendons. Measurements were made of the height of excised trapeziums, the distance from the metacarpal base to the scaphoid after trapeziectomy (trapeziectomy space height) at time zero, both loaded and unloaded, and at sequential loading cycles of 1,000, 2,000, 3,000, 4,000, 5,000, and 10,000 cycles.
RESULTS: Student t-test evaluation showed no significant differences between the groups in initial trapeziectomy space height (p = .10), postfixation trapeziectomy space height (p = .10), or loss of trapeziectomy space height between precycling and after 10,000 cycles (p = .80).
CONCLUSIONS: Suture button fixation maintains similar posttrapeziectomy space height and prevents subsidence of the thumb metacarpal when compared with K-wire fixation in this model. This technique may allow for earlier range of motion after the hematoma distraction arthroplasty.
Copyright © 2010 American Society for Surgery of the Hand. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2010        PMID: 21134614     DOI: 10.1016/j.jhsa.2010.09.007

Source DB:  PubMed          Journal:  J Hand Surg Am        ISSN: 0363-5023            Impact factor:   2.230


  11 in total

1.  Arthroscopic Trapeziectomy With Suture Button Suspensionplasty: A Retrospective Review of 153 Cases.

Authors:  Genevieve Landes; Michael P Gaspar; Peter Goljan; Sidney M Jacoby; Abdo Bachoura; Randall W Culp
Journal:  Hand (N Y)       Date:  2016-01-21

2.  Biomechanical Comparison of Suture-Button Suspensionplasty and LRTI for Basilar Thumb Arthritis.

Authors:  Mihir J Desai; David M Brogan; Marc J Richard; Suhail K Mithani; Fraser J Leversedge; David S Ruch
Journal:  Hand (N Y)       Date:  2016-04-05

3.  Suture-Button Device Stabilization Following Ring Finger Ray Amputation: A Comparative Cadaver Study.

Authors:  Emily N Morgan; Kenneth R Means; Adrian G Paez; Brent G Parks; Peter C Innis
Journal:  Hand (N Y)       Date:  2017-06-30

4.  Thumb Metacarpal Subsidence After Partial Trapeziectomy With Capsular Interposition Arthroplasty: A Biomechanical Study.

Authors:  Christina Salas; Deana M Mercer; Gavin O'Mahony; James Love; Dukens LaBaze; Moheb S Moneim
Journal:  Hand (N Y)       Date:  2016-03-08

5.  Arthroscopic Hemitrapeziectomy and Suture Button Suspensionplasty in the Treatment of First Carpometacarpal Joint Eaton-Littler Stage 2-3 Arthrosis.

Authors:  İsmail Bülent Özçelik; Meriç Uğurlar; Abdulkadir Sarı
Journal:  J Wrist Surg       Date:  2019-01-24

6.  Suture button suspension following trapeziectomy in a cadaver model.

Authors:  Yohan Song; Christopher A Cox; Jeffrey Yao
Journal:  Hand (N Y)       Date:  2013-06

7.  Four-Strand Versus 2-Strand Suture-Button Constructs in First Carpometacarpal Arthroplasty: A Biomechanical Study.

Authors:  Beatrice L Grasu; Andrew J Trontis; Brent G Parks; Raymond A Wittstadt
Journal:  Hand (N Y)       Date:  2018-04-19

Review 8.  Surgery for thumb (trapeziometacarpal joint) osteoarthritis.

Authors:  Anne Wajon; Toby Vinycomb; Emma Carr; Ian Edmunds; Louise Ada
Journal:  Cochrane Database Syst Rev       Date:  2015-02-23

9.  Basal joint osteoarthritis of the thumb: comparison of suture button versus abductor pollicis longus suspensionplasty.

Authors:  Kristopher R Avant; Jason A Nydick; Brian D White; Lisa Vaccaro; Alfred V Hess; Jeffrey D Stone
Journal:  Hand (N Y)       Date:  2015-03

10.  Patient functional outcomes with trapeziectomy alone versus trapeziectomy with TightRope(®).

Authors:  Arvind Mohan; Michael Shenouda; Hiba Ismail; Ankit Desai; Joshua Jacob; Tanaya Sarkhel
Journal:  J Orthop       Date:  2015-11-14
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.