Literature DB >> 21131654

Venous air embolism and intracardiac thrombus after pressurized fibrin glue during liver surgery.

F M Ebner1, A Paul, J Peters, M Hartmann.   

Abstract

After segmental liver resection, a fibrin glue aerosol was used to stop diffuse bleeding from the liver resection site. Immediately after pressurized administration, severe hypotension and bradycardia occurred, requiring cardiopulmonary resuscitation and inotropic support. Transoesophageal echocardiography demonstrated air in both ventricles deriving from the inferior vena cava; contractility of both ventricles was markedly reduced. In addition, a 3 cm floating thrombus was detected in the right ventricle. This case demonstrates that sprayed fibrin glue can cause life-threatening air embolism and intracardiac thrombus formation in liver surgery.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 21131654     DOI: 10.1093/bja/aeq336

Source DB:  PubMed          Journal:  Br J Anaesth        ISSN: 0007-0912            Impact factor:   9.166


  7 in total

1.  Fibrin glue for olecranon bursitis: a case report.

Authors:  David J Berkoff; Zachary W Sandbulte; Harry C Stafford; Joshua N Berkowitz
Journal:  Ther Adv Musculoskelet Dis       Date:  2016-02       Impact factor: 5.346

2.  Emergent limited perioperative transesophageal echocardiography: should new guidelines exist for limited echocardiography training for anesthesiologists?

Authors:  Yong G Peng; Gregory M Janelle
Journal:  Front Med       Date:  2012-07-26       Impact factor: 4.592

Review 3.  Use of Monsel solution to treat obstetrical hemorrhage: a review and comparison to other topical hemostatic agents.

Authors:  Devin T Miller; Dana M Roque; Alessandro D Santin
Journal:  Am J Obstet Gynecol       Date:  2015-01-08       Impact factor: 8.661

4.  Results from a First-in-Human Trial of a Novel Vascular Sealant.

Authors:  Hans-Joachim Florek; Jan Brunkwall; Karl-Heinz Orend; Ian Handley; John Pribble; Ronald Dieck
Journal:  Front Surg       Date:  2015-07-01

5.  Repeated cardiac arrest caused by an air embolism during hepatic resection: A case report.

Authors:  Li-Hui Luo; Zhi-You Peng; Sheng-Mei Zhu; Yong-Xing Yao
Journal:  Medicine (Baltimore)       Date:  2018-09       Impact factor: 1.889

6.  A Bio Polymeric Adhesive Produced by Photo Cross-Linkable Technique.

Authors:  Soliman Abdalla; Nabil Al-Aama; Maryam A Al-Ghamdi
Journal:  Polymers (Basel)       Date:  2016-08-10       Impact factor: 4.329

7.  Vascular air embolism.

Authors:  Stephanie Gordy; Susan Rowell
Journal:  Int J Crit Illn Inj Sci       Date:  2013-01
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.