Estimation of right atrial and ventricular hemodynamics by CT coronary angiography.

Raman S Dusaj1, Katherine C Michelis, Megan Terek, Reza Sanai, Rajat Mittal, Jannet F Lewis, Robert K Zeman, Brian G Choi.   

Abstract

BACKGROUND: Computed tomography coronary angiography (CTCA) provides an accurate noninvasive alternative to the invasive assessment of coronary artery disease. However, a specific limitation of CTCA is inability to assess hemodynamic data.
OBJECTIVE: We hypothesized that CTCA-derived measurements of contrast within the superior vena cava (SVC) and inferior vena cava (IVC) would correlate to echocardiographic estimations of right atrial and right ventricular pressures.
METHODS: Medical records of all patients who underwent both echocardiography and CTCA in our center were reviewed (n = 32). Standard CTCA was performed with a 64-detector CT using test-bolus method for image acquisition timing and iso-osmolar contrast injection through upper extremity vein. The length of the column of contrast reflux into the inferior vena cava (IVC) was correlated to echocardiographically determine tricuspid regurgitation jet velocity (TRV). SVC area change with contrast injection at the level of the bifurcation of the pulmonary artery was also correlated with IVC sniff response by echocardiogram.
RESULTS: The reflux column length was interpretable in 27 of 32 patients with a mean length of 10.1 ± 1.1 mm, and a significant bivariate correlation was observed between reflux column length and the tricuspid regurgitant jet velocity (r = 0.84; P < .0001). Mean SVC distensibility ratio was 0.63 ± 0.03; mean IVC sniff response ratio was 0.53 ± 0.03. SVC distensibility correlated to IVC sniff response with a Pearson r of 0.57 (P = .04).
CONCLUSION: Quantification of IVC and SVC contrast characteristics during CTCA provides a feasible and potentially accurate method of estimating right atrial and ventricular pressure.
Copyright © 2011 Society of Cardiovascular Computed Tomography. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2010        PMID: 21130724     DOI: 10.1016/j.jcct.2010.10.005

Source DB:  PubMed          Journal:  J Cardiovasc Comput Tomogr        ISSN: 1876-861X


  1 in total

1.  Cardiac tamponade: contrast reflux as an indicator of cardiac chamber equalization.

Authors:  Foeke Jacob Harmen Nauta; Wernard Aat Antoine Borstlap; Michael Stella; Zain Khalpey
Journal:  J Cardiothorac Surg       Date:  2012-05-31       Impact factor: 1.637

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.