Literature DB >> 21127076

Telemetric monitoring of fetal blood pressure and heart rate in the freely moving pregnant sheep: a feasibility study.

Khalil N Abi-Nader1, Vedanta Mehta, S W Steven Shaw, Tom Bellamy, Neil Smith, Laura Millross, Beth Laverick, Elisa Filippi, Michael Boyd, Donald M Peebles, Anna L David.   

Abstract

Remote telemetric monitoring of fetal haemodynamics in pregnant sheep would allow unrestricted animal movement, minimize suffering and distress, and improve animal welfare, while enhancing the quality of data collected. This may also be useful in clinical practice following fetal surgery. Using an open fetal surgical technique at approximately two-thirds of gestation, we implanted the catheter of a D70-PCTP haemodynamic telemetric device (Data Sciences International, Tilburg, The Netherlands) into the carotid artery of the fetal sheep (n = 4). The attached transmitter was secured to the posterior aspect of the maternal anterior abdominal wall. Two receivers, with a range of 1 m each, were sited in an 11 m² sheep enclosure to maximize animal freedom while allowing continuous monitoring of the ewe. The receivers were connected by cable to a nearby computer. In the first two procedures, both fetuses died eight and 12 days after surgery, and the catheter tip was observed to be lying in the bicarotid trunk. In the next two procedures the catheter tip was threaded further upstream from the insertion point, in an attempt to reach the fetal aorta, and both fetuses survived until the scheduled postmortem examination at the end of pregnancy. After catheter implantation, fetal blood pressure (BP) and heart rate (HR) were successfully recorded continuously for seven days and then hourly per day for a further three weeks. The fetal BP and HR values were in the normal range for healthy sheep fetuses.

Entities:  

Mesh:

Year:  2010        PMID: 21127076     DOI: 10.1258/la.2010.010059

Source DB:  PubMed          Journal:  Lab Anim        ISSN: 0023-6772            Impact factor:   2.471


  3 in total

1.  Use of radiotelemetry to assess perinatal cardiac function in the ovine fetus and newborn.

Authors:  A Antolic; C E Wood; M Keller-Wood
Journal:  Am J Physiol Regul Integr Comp Physiol       Date:  2017-08-30       Impact factor: 3.619

2.  Evaluation of fetal exposure to external loud noise using a sheep model: quantification of in utero acoustic transmission across the human audio range.

Authors:  Pierre Gélat; Anna L David; Seyyed Reza Haqhenas; Julian Henriques; Aude Thibaut de Maisieres; Tony White; Eric Jauniaux
Journal:  Am J Obstet Gynecol       Date:  2019-05-29       Impact factor: 10.693

3.  Doppler sonography for evaluation of hemodynamic characteristics of fetal umbilicus in Beetal goats.

Authors:  Kailash Kumar; Ramesh K Chandolia; Sandeep Kumar; Tarachand Jangir; Ram Avatar Luthra; Sonu Kumari; Sarvan Kumar
Journal:  Vet World       Date:  2015-03-28