Bioimpedance: a novel method for the determination of extravascular lung water.

J L Zellner1, F G Spinale, F A Crawford.   

Abstract

Extravascular lung water (EVLW) can be measured using the double indicator dilution technique (DD). However, because this method is highly invasive and complicated, its clinical used has been limited. In theory, changes in thoracic conductivity, or bioimpedance (BI), can reflect changes in EVLW. However, past studies were unable to directly quantitate changes in EVLW since the contribution of dynamic variables such as ventricular volumes, hematocrit (HCT), and EVLW to this impedance signal could not be discerned. Recent studies have shown that a thermodilution pulmonary artery catheter mounted with a fast response thermistor accurately measures right ventricular end-diastolic volume (RVEDV). With changes in the RVEDV and HCT known, the contribution of EVLW to the bioimpedance signal may be isolated and used to more directly measure changes in EVLW. This hypothesis was tested by creating acute sepsis in seven pigs by infusion of Pseudomonas aeruginosa. Changes in EVLW from baseline were measured using DD at 30 min and at 1, 2, and 4 hr and compared with the change in EVLW computed from a mathematical model comprising the measured changes in BI, RVEDV, and HCT at the same time points. Changes in EVLW using DD and BI were significantly correlated over the length of the study (r = 0.85, P less than 0.01). In early sepsis (30 min), BI overestimated EVLW when compared with DD (P less than 0.05). However, at 1, 2, and 4 hr there was no significant difference between the two methods. In conclusion, the use of bioimpedance and a volumetric catheter may provide a relatively simple and reliable method for continuously monitoring changes in EVLW in the intensive care setting.

Entities:  

Mesh:

Year:  1990        PMID: 2112668     DOI: 10.1016/0022-4804(90)90012-q

Source DB:  PubMed          Journal:  J Surg Res        ISSN: 0022-4804            Impact factor:   2.192


  5 in total

1.  Differences in weight perception among blacks and whites.

Authors:  Yolanda Hendley; Liping Zhao; Dorothy L Coverson; Rebecca Din-Dzietham; Alanna Morris; Arshed A Quyyumi; Gary H Gibbons; Viola Vaccarino
Journal:  J Womens Health (Larchmt)       Date:  2011-10-11       Impact factor: 2.681

2.  The measurement of lung water.

Authors: 
Journal:  Crit Care       Date:  1999       Impact factor: 9.097

3.  Prototype development of an electrical impedance based simultaneous respiratory and cardiac monitoring system for gated radiotherapy.

Authors:  Kirpal Kohli; Jeff Liu; Devin Schellenberg; Anand Karvat; Ash Parameswaran; Parvind Grewal; Steven Thomas
Journal:  Biomed Eng Online       Date:  2014-10-14       Impact factor: 2.819

4.  Design of Howland Current Sources Using Differential Evolution Optimization.

Authors:  Kaue Felipe Morcelles; Lucas Hermann Negri; Pedro Bertemes-Filho
Journal:  J Electr Bioimpedance       Date:  2020-12-31

5.  Internal thoracic impedance - a useful method for expedient detection and convenient monitoring of pleural effusion.

Authors:  Gideon Charach; Olga Rubalsky; Lior Charach; Alexander Rabinovich; Ori Argov; Ori Rogowski; Jacob George
Journal:  PLoS One       Date:  2015-04-28       Impact factor: 3.240

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.