Literature DB >> 21122861

Double calibration: an accurate, reliable and easy-to-use method for 3D scapular motion analysis.

Sylvain Brochard1, Mathieu Lempereur, Olivier Rémy-Néris.   

Abstract

The most recent non-invasive methods for the recording of scapular motion are based on an acromion marker (AM) set and a single calibration (SC) of the scapula in a resting position. However, this method fails to accurately measure scapular kinematics above 90° of arm elevation, due to soft tissue artifacts of the skin and muscles covering the acromion. The aim of this study was to evaluate the accuracy, and inter-trial and inter-session repeatability of a double calibration method (DC) in comparison with SC. The SC and DC data were measured with an optoelectronic system during arm flexion and abduction at different angles of elevation (0-180°). They were compared with palpation of the scapula using a scapula locator. DC data was not significantly different from palpation for 5/6 axes of rotation tested (Y, X, and Z in abduction and flexion), where as SC showed significant differences for 5/6 axes. The root mean square errors ranged from 2.96° to 4.48° for DC and from 6° to 9.19° for SC. The inter-trial repeatability was good to excellent for SC and DC. The inter-session repeatability was moderate to excellent for SC and moderate to good for DC. Coupling AM and DC is an easy-to-use method, which yields accurate and reliable measurements of scapular kinematics for the complete range of arm motion. It can be applied to the measurement of shoulder motion in many fields (sports, orthopaedics, and rehabilitation), especially when large ranges of arm motion are required.
Copyright © 2010 Elsevier Ltd. All rights reserved.

Entities:  

Mesh:

Year:  2010        PMID: 21122861     DOI: 10.1016/j.jbiomech.2010.11.017

Source DB:  PubMed          Journal:  J Biomech        ISSN: 0021-9290            Impact factor:   2.712


  8 in total

Review 1.  Collecting shoulder kinematics with electromagnetic tracking systems and digital inclinometers: A review.

Authors:  Daniel C Hannah; Jason S Scibek
Journal:  World J Orthop       Date:  2015-11-18

2.  The latissimus dorsi tendon functions as an external rotator after arthroscopic-assisted transfer for massive irreparable posterosuperior rotator cuff tears.

Authors:  Olimpio Galasso; Matteo Mantovani; Marco Muraccini; Antonella Berardi; Massimo De Benedetto; Nicola Orlando; Giorgio Gasparini; Roberto Castricini
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2019-12-06       Impact factor: 4.342

3.  IMU-based sensor-to-segment multiple calibration for upper limb joint angle measurement-a proof of concept.

Authors:  Mahdi Zabat; Amina Ababou; Noureddine Ababou; Raphaël Dumas
Journal:  Med Biol Eng Comput       Date:  2019-08-30       Impact factor: 2.602

4.  Association between changes in pain or function scores and changes in scapular rotations in patients with subacromial shoulder pain: a prospective cohort study.

Authors:  Zohreh Jafarian Tangrood; Gisela Sole; Daniel Cury Ribeiro
Journal:  Arch Physiother       Date:  2022-08-15

5.  Characteristics of the scapula movement during shoulder elevation depend on posture.

Authors:  Kazuyuki Yabata; Tsutomu Fukui
Journal:  J Phys Ther Sci       Date:  2022-07-01

6.  Three-Dimensional Quantitative Evaluation of the Scapular Skin Marker Movements in the Upright Posture.

Authors:  Yuki Yoshida; Noboru Matsumura; Yoshitake Yamada; Minoru Yamada; Yoichi Yokoyama; Azusa Miyamoto; Masaya Nakamura; Takeo Nagura; Masahiro Jinzaki
Journal:  Sensors (Basel)       Date:  2022-08-29       Impact factor: 3.847

7.  Definition of anatomical zero positions for assessing shoulder pose with 3D motion capture during bilateral abduction of the arms.

Authors:  Oliver Rettig; Britta Krautwurst; Michael W Maier; Sebastian I Wolf
Journal:  BMC Musculoskelet Disord       Date:  2015-12-09       Impact factor: 2.362

8.  A survey of human shoulder functional kinematic representations.

Authors:  Rakesh Krishnan; Niclas Björsell; Elena M Gutierrez-Farewik; Christian Smith
Journal:  Med Biol Eng Comput       Date:  2018-10-26       Impact factor: 2.602

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.