Literature DB >> 21119167

Cementless total hip replacement using second-generation components: a 12- to 16-year follow-up.

J R McLaughlin1, K R Lee.   

Abstract

We reviewed 123 second-generation uncemented total hip replacements performed on 115 patients by a single surgeon between 1993 and 1994. The acetabular component used in all cases was a fully porous-coated threaded hemispheric titanium shell (T-Tap ST) with a calcium ion stearate-free, isostatically compression-moulded polyethylene liner. The titanium femoral component used was a Taperloc with a reduced distal stem. No patient was lost to follow-up. Complete clinical and radiological follow-up was obtained for all 123 hips at a mean of 14 years (12 to 16). One femoral component was revised after a fracture, and three acetabular components for aseptic loosening. No additional femoral or acetabular components were judged loose by radiological criteria. Mild proximal femoral osteolysis was identified in two hips and minor acetabular osteolysis was present in four. The mean rate of penetration of the femoral head was 0.036 mm/year (0.000 to 0.227). These findings suggest that refinements in component design may be associated with excellent long-term fixation in cementless primary total hip replacement.

Entities:  

Mesh:

Year:  2010        PMID: 21119167     DOI: 10.1302/0301-620X.92B12.24582

Source DB:  PubMed          Journal:  J Bone Joint Surg Br        ISSN: 0301-620X


  11 in total

1.  CORR Insights®: Two- to 4-year Followup of a Short Stem THA Construct: Excellent Fixation, Thigh Pain a Concern.

Authors:  Christophe Nich
Journal:  Clin Orthop Relat Res       Date:  2016-08-09       Impact factor: 4.176

2.  Clinical Faceoff: Where Are We Going With Femoral Stem Fixation in THA?

Authors:  Joseph T Moskal; Susan G Capps; C Anderson Engh; Anders Troelsen
Journal:  Clin Orthop Relat Res       Date:  2016-03-28       Impact factor: 4.176

3.  Radiographic evaluation of linear wear of bipolar hemiarthroplasty devices in vivo.

Authors:  Nobuhiro Kaku; Shouhei Noda; Tomonori Tabata; Hiroaki Tagomori; Hiroshi Tsumura
Journal:  J Clin Orthop Trauma       Date:  2018-07-20

4.  Short uncemented stems allow greater femoral flexibility and may reduce peri-prosthetic fracture risk: a dry bone and cadaveric study.

Authors:  Christopher Jones; Adeel Aqil; Susannah Clarke; Justin P Cobb
Journal:  J Orthop Traumatol       Date:  2015-02-21

Review 5.  Short-stem prostheses in primary total hip arthroplasty: A meta-analysis of randomized controlled trials.

Authors:  Shao-Chuan Huo; Fan Wang; Lu-Jue Dong; Wei Wei; Jing-Qi Zeng; Hong-Xing Huang; Qing-Min Han; Rui-Qi Duan
Journal:  Medicine (Baltimore)       Date:  2016-10       Impact factor: 1.889

6.  Finite Element Analysis of porously punched prosthetic short stem virtually designed for simulative uncemented Hip Arthroplasty.

Authors:  Matthew Jian-Qiao Peng; Hai-Yan Chen; Yong Hu; XiangYang Ju; Bo Bai
Journal:  BMC Musculoskelet Disord       Date:  2017-07-11       Impact factor: 2.362

7.  Long-term bone remodelling around 'legendary' cementless femoral stems.

Authors:  Charles Rivière; Guido Grappiolo; Charles A Engh; Jean-Pierre Vidalain; Antonia-F Chen; Nicolas Boehler; Jihad Matta; Pascal-André Vendittoli
Journal:  EFORT Open Rev       Date:  2018-02-26

8.  10-year results of the uncemented Allofit press-fit cup in young patients.

Authors:  Marcus R Streit; Stefan Weiss; Franziska Andreas; Thomas Bruckner; Tilman Walker; J Philippe Kretzer; Volker Ewerbeck; Christian Merle
Journal:  Acta Orthop       Date:  2014-05-30       Impact factor: 3.717

9.  Stable fixation of a madreporic Lord femoral prosthesis at 31-year follow-up in a total hip arthroplasty: A case report.

Authors:  Fernando M Judas; Joana Fonseca Ferreira; Rui Freitas Dias; Francisco M Lucas
Journal:  Int J Surg Case Rep       Date:  2015-12-14

10.  Human Skeletal Stem Cell Response to Multiscale Topography Induced by Large Area Electron Beam Irradiation Surface Treatment.

Authors:  Vitali Goriainov; Richard B Cook; James W Murray; John C Walker; Douglas G Dunlop; Adam T Clare; Richard O C Oreffo
Journal:  Front Bioeng Biotechnol       Date:  2018-07-24
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.