Literature DB >> 21118756

Optical reconstruction of high-speed surface dynamics in an uncontrollable environment.

Georg Luegmair1, Stefan Kniesburges, Maik Zimmermann, Alexander Sutor, Ulrich Eysholdt, Michael Döllinger.   

Abstract

The ability to communicate with our voice can be regarded as the concatenation of the two processes "phonation" and "modulation." These take place in the larynx and palatal and oral region, respectively. During phonation the audible primary voice signal is created by mutual reaction of vocal folds with the exhaled air stream of the lungs. The underlying interactions of masses, fluids and acoustics have yet to be identified and understood. One part of the primary signal's acoustical source are vortex induced vibrations, as e.g., created by the Coandăeffect in the air stream. The development of these vorteces is determined by the shape and 3-D movements of the vocal folds in the larynx. Current clinical in vivo research methods for vocal folds do not deliver data of satisfactory quality for fundamental research, e.g., an endoscope is limited to 2-D image information. Based hereupon, a few improved methods have been presented, however delivering only selective 3-D information, either for a single point or a line. This stands in contrast to the 3-D motions of the entire vocal fold surface. More complex imaging methods, such as MRI, do not deliver information in real-time. Thus, it is necessary to develop an easily applicable, more improved examination method, which allows for 3-D data of the vocal folds surfaces to be obtained. We present a method to calibrate a 3-D reconstruction setup including a laser projection system and a high-speed camera. The setup is designed with miniaturization and an in vivo application in mind. The laser projection system generates a divergent grid of 196 laser dots by diffraction gratings. It is calibrated with a planar calibration target through planar homography. In general, the setup allows to reconstruct the topology of a surface at high frame rates (up to 4000 frames per second) and in uncontrollable environments, as e.g., given by the lighting situation (little to no ambient light) and varying texture (e.g., varying grade of reflection) in the human larynx. In particular, this system measures the 3-D vocal fold surface dynamics during phonation. Applied to synthetic data, the calibration is shown to be robust (error approximately 0.5 μm) regarding noise and systematic errors. Experimental data gained with a linear z -stage proved that the system reconstructs the 3-D coordinates of points with an error at approximately 15 μm. The method was applied exemplarily to reconstruct porcine and artificial vocal folds' surfaces during phonation. Local differences such as asymmetry between left and right fold dynamics, as well as global parameters, such as opening and closing speed and maximum displacements, were identified and quantified.

Entities:  

Mesh:

Year:  2010        PMID: 21118756     DOI: 10.1109/TMI.2010.2055578

Source DB:  PubMed          Journal:  IEEE Trans Med Imaging        ISSN: 0278-0062            Impact factor:   10.048


  18 in total

Review 1.  [Current methods for modelling voice production].

Authors:  M Döllinger; S Kniesburges; M Kaltenbacher; M Echternach
Journal:  HNO       Date:  2016-02       Impact factor: 1.284

2.  Method for Vertical Calibration of Laser-Projection Transnasal Fiberoptic High-Speed Videoendoscopy.

Authors:  Hamzeh Ghasemzadeh; Dimitar D Deliyski; David S Ford; James B Kobler; Robert E Hillman; Daryush D Mehta
Journal:  J Voice       Date:  2019-05-29       Impact factor: 2.009

3.  Vocal fold vibration measurements using laser Doppler vibrometry.

Authors:  Alfred Chan; Luc Mongeau; Karen Kost
Journal:  J Acoust Soc Am       Date:  2013-03       Impact factor: 1.840

4.  Dynamic vocal fold parameters with changing adduction in ex-vivo hemilarynx experiments.

Authors:  Michael Döllinger; David A Berry; Stefan Kniesburges
Journal:  J Acoust Soc Am       Date:  2016-05       Impact factor: 1.840

5.  Synchronized, concurrent optical coherence tomography and videostroboscopy for monitoring vocal fold morphology and kinematics.

Authors:  Gopi Maguluri; Daryush Mehta; James Kobler; Jesung Park; Nicusor Iftimia
Journal:  Biomed Opt Express       Date:  2019-08-06       Impact factor: 3.732

6.  Development of a time-dependent numerical model for the assessment of non-stationary pharyngoesophageal tissue vibrations after total laryngectomy.

Authors:  Björn Hüttner; Georg Luegmair; Rita R Patel; Anke Ziethe; Ulrich Eysholdt; Christopher Bohr; Irina Sebova; Marion Semmler; Michael Döllinger
Journal:  Biomech Model Mechanobiol       Date:  2014-05-27

7.  Effects of the epilarynx area on vocal fold dynamics and the primary voice signal.

Authors:  Michael Döllinger; David A Berry; Georg Luegmair; Björn Hüttner; Christopher Bohr
Journal:  J Voice       Date:  2011-06-25       Impact factor: 2.009

8.  Computation of physiological human vocal fold parameters by mathematical optimization of a biomechanical model.

Authors:  Anxiong Yang; Michael Stingl; David A Berry; Jorg Lohscheller; Daniel Voigt; Ulrich Eysholdt; Michael Dollinger
Journal:  J Acoust Soc Am       Date:  2011-08       Impact factor: 1.840

9.  Measurement of glottal cycle characteristics between children and adults: physiological variations.

Authors:  Rita R Patel; Denis Dubrovskiy; Michael Döllinger
Journal:  J Voice       Date:  2014-03-12       Impact factor: 2.009

10.  [3D visualization and analysis of vocal fold dynamics].

Authors:  C Bohr; M Döllinger; S Kniesburges; M Traxdorf
Journal:  HNO       Date:  2016-04       Impact factor: 1.284

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.