Ki Wan Bong1, Stephen C Chapin, Daniel C Pregibon, David Baah, Tamara M Floyd-Smith, Patrick S Doyle.
Abstract
We present the construction and operation of a compressed-air driven flow system that can be used for a variety of microfluidic applications that require rapid dynamic response and precise control of multiple inlet streams. With the use of inexpensive and readily available parts, we describe how to assemble this versatile control system and further explore its utility in continuous- and pulsed-flow microfluidic procedures for the synthesis and analysis of microparticles.Mesh:
Substances:
Year: 2010 PMID: 21116544 DOI: 10.1039/c0lc00303d