Literature DB >> 21116199

The reliability of linear position transducer and force plate measurement of explosive force-time variables during a loaded jump squat in elite athletes.

Keir T Hansen1, John B Cronin, Michael J Newton.   

Abstract

The best method of assessing muscular force qualities during isoinertial stretch shorten cycle lower body movements remains a subject of much debate. This study had 2 purposes: Firstly, to calculate the interday reliability of peak force (PF) measurement and a variety of force-time measures, and, secondly, to compare the reliability of the 2 most common technologies for measuring force during loaded jump squats, the linear position transducer (PT), and the force plate (FP). Twenty-five male elite level rugby union players performed 3 rebound jump squats with a 40-kg external load on 2 occasions 1 week apart. Vertical ground reaction forces (GRFs) were directly measured via an FP, and force was differentiated from position data collected using a PT. From these data, a number of force-time variables were calculated for both the FP and PT. Intraclass correlation coefficient (ICC), coefficient of variation (CV), and percent change in the mean were used as measures of between-session reliability. Additionally, Pearson's product moment correlation coefficients were used to investigate intercorrelations between variables and technologies. Both FP and PT were found to be a reliable means of measuring PF (ICC = 0.88-0.96, CV = 2.3-4.8%), and the relationship between the 2 technologies was very high and high for days 1 and 2, respectively (r = 0.67-0.88). Force-time variables calculated from FP data tended to have greater relative and absolute consistency (ICC = 0.70-0.96, CV = 5.1-51.8%) than those calculated from differentiated PT data (ICC = 0.18-0.95, CV = 7.7-93.6%). Intercorrelations between variables ranged from trivial to practically perfect (r = 0.00-1.00). It was concluded that PF can be measured reliably with both FP and PT technologies, and these measurements are related. A number of force-time values can also be reliably calculated via the use of GRF data. Although some of these force-time variables can be reliably calculated using position data, variation of measurement is generally greater when using position data to calculate force.

Mesh:

Year:  2011        PMID: 21116199     DOI: 10.1519/JSC.0b013e3181d85972

Source DB:  PubMed          Journal:  J Strength Cond Res        ISSN: 1064-8011            Impact factor:   3.775


  3 in total

Review 1.  A brief review of strength and ballistic assessment methodologies in sport.

Authors:  Daniel Travis McMaster; Nicholas Gill; John Cronin; Michael McGuigan
Journal:  Sports Med       Date:  2014-05       Impact factor: 11.136

2.  Velocity Loss Thresholds Reliably Control Kinetic and Kinematic Outputs during Free Weight Resistance Training.

Authors:  Madison Pearson; Amador García-Ramos; Matthew Morrison; Carlos Ramirez-Lopez; Nicholas Dalton-Barron; Jonathon Weakley
Journal:  Int J Environ Res Public Health       Date:  2020-09-07       Impact factor: 3.390

3.  Does a linear position transducer placed on a stick and belt provide sufficient validity and reliability of countermovement jump performance outcomes?

Authors:  Vladimír Hojka; Petr Šťastný; James J Tufano; Dan Omcirk; Martin T Janikov; Martin Komarc; Radim Jebavý
Journal:  Biol Sport       Date:  2021-04-21       Impact factor: 2.806

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.