Literature DB >> 21113073

Evaluation of a new method for the measurement of corneal thickness in eye bank posterior corneal lenticules using Anterior Segment Optical Coherence Tomography.

Domenico Amato1, Marco Lombardo, Francesco Oddone, Mario Nubile, Rossella A M Colabelli Gisoldi, Carlo M Villani, Sonia Yoo, Jean-Marie Parel, Augusto Pocobelli.   

Abstract

BACKGROUND/AIMS: To preliminarily evaluate the repeatability of central corneal thickness (CCT) measurements performed with Anterior Segment Optical Coherence Tomography (AS-OCT) on eye bank posterior corneal lenticules.
METHODS: Six donor lenticules were created with a 350 μm head microkeratome (Moria, Antony, France). All donor tissues were stored at 4°C in Eusol-C solution (Alchimia S.r.l, Ponte S. Nicolò, Italy), without the anterior cornea lamella. The CCT of each lenticule, maintained in the glass phial, was measured using a commercial AS-OCT instrument (Visante, Carl Zeiss Meditec, Dublin, California, USA) and a specially designed adaptor immediately and 4, 24 and 48 hours after dissection. Immediately after AS-OCT, CCT values were measured with the ultrasound pachymetry method used at the Eye Bank.
RESULTS: The mean donor cornea central thickness was 647±36 μm and 660 ± 38 μm (p=0.001) as measured by AS-OCT and ultrasound, respectively; immediately after dissection, CCT values of posterior lenticules were 235 ± 43 μm and 248 ± 44 μm, respectively (p=0.001). No statistically significant changes in CCT values of donor lenticules were assessed over the 48 h period with both methods. There was a high level of agreement, evidenced by Bland-Altman analysis, between the two methods of pachymetry.
CONCLUSION: AS-OCT, with the corneal tissue in the vial, was revealed to be a repeatable and reliable method for measuring posterior donor lenticule central thickness. Lenticule CCT values measured with the investigational AS-OCT method were on average 10 μm thinner than those measured with the established ultrasound method.

Entities:  

Mesh:

Year:  2010        PMID: 21113073     DOI: 10.1136/bjo.2010.190595

Source DB:  PubMed          Journal:  Br J Ophthalmol        ISSN: 0007-1161            Impact factor:   4.638


  3 in total

1.  "OSMO-UT-DSAEK" using THIN-C medium.

Authors:  F Bucher; S Roters; A Mellein; D Hos; L M Heindl; C Cursiefen; M Hermann
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2013-08-02       Impact factor: 3.117

Review 2.  Applications of Anterior Segment Optical Coherence Tomography in Cornea and Ocular Surface Diseases.

Authors:  Sang Beom Han; Yu-Chi Liu; Karim Mohamed Noriega; Jodhbir S Mehta
Journal:  J Ophthalmol       Date:  2016-09-19       Impact factor: 1.909

3.  Deformation velocity imaging using optical coherence tomography and its applications to the cornea.

Authors:  Samuel Lawman; Peter W Madden; Vito Romano; Yue Dong; Sharon Mason; Bryan M Williams; Stephen B Kaye; Colin E Willoughby; Simon P Harding; Yao-Chun Shen; Yalin Zheng
Journal:  Biomed Opt Express       Date:  2017-11-13       Impact factor: 3.732