Literature DB >> 21112601

Proof of concept: In vitro measurement of correlation between radiodensity and ultrasound echo response of ovine vertebral bodies.

Jin Ho Chang1, David T Raphael, Yao Ping Zhang, K Kirk Shung.   

Abstract

An acoustic guidance method for pedicle screw placement during spine fixation surgery was recently investigated, with a view toward preventing complications such as injury to the spinal cord, thecal sac, and spinal nerve roots due to screw misplacement. The method relies upon the change in the ultrasound amplitude reflected at different sites-from the outer posterior cortex, through the pedicle, and towards the distal ventral cortex. The amplitude change was empirically observed through in vitro measurement of ultrasound amplitude at the different sites by inserting a 2.5-MHz single element transducer into a vertebral body through insertion pathway created by an advancing screw. This paper provides a theoretical and experimental rationale behind these empirical findings and distance-dependent correlation coefficients between amplitude and bone mineral density within the vertebral body, which approached 97%. Copyright Â
© 2010 Elsevier B.V. All rights reserved.

Entities:  

Mesh:

Year:  2010        PMID: 21112601      PMCID: PMC3022323          DOI: 10.1016/j.ultras.2010.10.008

Source DB:  PubMed          Journal:  Ultrasonics        ISSN: 0041-624X            Impact factor:   2.890


  6 in total

1.  Complications associated with pedicle screws.

Authors:  J E Lonstein; F Denis; J H Perra; M R Pinto; M D Smith; R B Winter
Journal:  J Bone Joint Surg Am       Date:  1999-11       Impact factor: 5.284

2.  Ultrasonic characterization of human cancellous bone using transmission and backscatter measurements: relationships to density and microstructure.

Authors:  S Chaffaî; F Peyrin; S Nuzzo; R Porcher; G Berger; P Laugier
Journal:  Bone       Date:  2002-01       Impact factor: 4.398

3.  Role of cortical and cancellous bone of the vertebral pedicle in implant fixation.

Authors:  H L Defino; J R Vendrame
Journal:  Eur Spine J       Date:  2001-08       Impact factor: 3.134

4.  Development of a method for ultrasound-guided placement of pedicle screws.

Authors:  Muris Mujagić; Howard J Ginsberg; Richard S C Cobbold
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2008       Impact factor: 2.725

5.  A-Mode ultrasound guidance for pedicle screw advancement in ovine vertebral bodies.

Authors:  David T Raphael; Jin Ho Chang; Yao Ping Zhang; David Kudija; Thomas C Chen; K Kirk Shung
Journal:  Spine J       Date:  2010-03-27       Impact factor: 4.166

6.  Effects of spinal instrumentation on fusion of the lumbosacral spine.

Authors:  F J Schwab; D G Nazarian; F Mahmud; C B Michelsen
Journal:  Spine (Phila Pa 1976)       Date:  1995-09-15       Impact factor: 3.468

  6 in total
  1 in total

1.  Design and Fabrication of Double-Focused Ultrasound Transducers to Achieve Tight Focusing.

Authors:  Jihun Jang; Jin Ho Chang
Journal:  Sensors (Basel)       Date:  2016-08-06       Impact factor: 3.576

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.