Literature DB >> 21110613

Influence of cancellous bone microstructure on two ultrasonic wave propagations in bovine femur: an in vitro study.

Katsunori Mizuno1, Hiroki Somiya, Tomohiro Kubo, Mami Matsukawa, Takahiko Otani, Toshiyuki Tsujimoto.   

Abstract

The influence of cancellous bone microstructure on the ultrasonic wave propagation of fast and slow waves was experimentally investigated. Four spherical cancellous bone specimens extracted from two bovine femora were prepared for the estimation of acoustical and structural anisotropies of cancellous bone. In vitro measurements were performed using a PVDF transducer (excited by a single sinusoidal wave at 1 MHz) by rotating the spherical specimens. In addition, the mean intercept length (MIL) and bone volume fraction (BV/TV) were estimated by X-ray micro-computed tomography. Separation of the fast and slow waves was clearly observed in two specimens. The fast wave speed was strongly dependent on the wave propagation direction, with the maximum speed along the main trabecular direction. The fast wave speed increased with the MIL. The slow wave speed, however, was almost constant. The fast wave speeds were statistically higher, and their amplitudes were statistically lower in the case of wave separation than in that of wave overlap.

Entities:  

Mesh:

Year:  2010        PMID: 21110613     DOI: 10.1121/1.3493444

Source DB:  PubMed          Journal:  J Acoust Soc Am        ISSN: 0001-4966            Impact factor:   1.840


  12 in total

1.  Estimation of in vivo cortical bone thickness using ultrasonic waves.

Authors:  Isao Mano; Kaoru Horii; Hiroshi Hagino; Takami Miki; Mami Matsukawa; Takahiko Otani
Journal:  J Med Ultrason (2001)       Date:  2015-02-26       Impact factor: 1.314

2.  Fast and slow wave detection in bovine cancellous bone in vitro using bandlimited deconvolution and Prony's method.

Authors:  Keith Wear; Yoshiki Nagatani; Katsunori Mizuno; Mami Matsukawa
Journal:  J Acoust Soc Am       Date:  2014-10       Impact factor: 1.840

3.  Enhanced correlation between quantitative ultrasound and structural and mechanical properties of bone using combined transmission-reflection measurement.

Authors:  Liangjun Lin; Wei Lin; Yi-Xian Qin
Journal:  J Acoust Soc Am       Date:  2015-03       Impact factor: 1.840

4.  Estimation of fast and slow wave properties in cancellous bone using Prony's method and curve fitting.

Authors:  Keith A Wear
Journal:  J Acoust Soc Am       Date:  2013-04       Impact factor: 1.840

5.  Ultrasound to assess bone quality.

Authors:  Kay Raum; Quentin Grimal; Peter Varga; Reinhard Barkmann; Claus C Glüer; Pascal Laugier
Journal:  Curr Osteoporos Rep       Date:  2014-06       Impact factor: 5.096

6.  Time-domain separation of interfering waves in cancellous bone using bandlimited deconvolution: simulation and phantom study.

Authors:  Keith A Wear
Journal:  J Acoust Soc Am       Date:  2014-04       Impact factor: 1.840

7.  Principal trabecular structural orientation predicted by quantitative ultrasound is strongly correlated with μFEA determined anisotropic apparent stiffness.

Authors:  Liangjun Lin; Han Yuen Oon; Wei Lin; Yi-Xian Qin
Journal:  Biomech Model Mechanobiol       Date:  2014-01-14

Review 8.  Mechanisms of Interaction of Ultrasound With Cancellous Bone: A Review.

Authors:  Keith A Wear
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2019-10-16       Impact factor: 2.725

Review 9.  New perspectives in echographic diagnosis of osteoporosis on hip and spine.

Authors:  Sergio Casciaro; Francesco Conversano; Paola Pisani; Maurizio Muratore
Journal:  Clin Cases Miner Bone Metab       Date:  2015-10-26

10.  Prediction of trabecular bone principal structural orientation using quantitative ultrasound scanning.

Authors:  Liangjun Lin; Jiqi Cheng; Wei Lin; Yi-Xian Qin
Journal:  J Biomech       Date:  2012-05-05       Impact factor: 2.712

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.