Alternatives to the mercury sphygmomanometer.

Susan Buchanan1, Peter Orris, Joshua Karliner.   

Abstract

The mercury sphygmomanometer was introduced over 100 years ago. Mercury, however, is a potent human neurotoxin. An international effort has developed to eliminate health-care sources of mercury--the thermometer and sphygmomanometer--and replace them with less toxic alternatives. There is concern regarding the accuracy of these alternative devices. We conducted a literature review of articles published between 1995 and 2009 evaluating the accuracy of mercury, aneroid, and oscillometric blood pressure devices. Mercury sphygmomanometers fared the best although they do not always perform as expected, failing calibration tests between 1 and 28 per cent of the time. Up to 61 per cent of aneroid sphygmomanometers failed. Recently calibrated aneroid devices performed well. Oscillometric devices were less studied and their performance was variable. All three devices showed variable performance. They should be validated before purchase and calibrated on a regular basis.

Entities:  

Mesh:

Year:  2010        PMID: 21109765     DOI: 10.1057/jphp.2010.38

Source DB:  PubMed          Journal:  J Public Health Policy        ISSN: 0197-5897            Impact factor:   2.222


  5 in total

1.  Baseline check of blood pressure readings of an automated device in severe pre-eclampsia and healthy normotensive pregnancy.

Authors:  Nnabuike C Ngene; Jagidesa Moodley
Journal:  Pregnancy Hypertens       Date:  2018-03-01       Impact factor: 2.899

2.  Pathological periodontal pockets are associated with raised diastolic blood pressure in obese adolescents.

Authors:  Cecilia C Zeigler; Biniyam Wondimu; Claude Marcus; Thomas Modéer
Journal:  BMC Oral Health       Date:  2015-03-24       Impact factor: 2.757

Review 3.  Sources of inaccuracy in the measurement of adult patients' resting blood pressure in clinical settings: a systematic review.

Authors:  Noa Kallioinen; Andrew Hill; Mark S Horswill; Helen E Ward; Marcus O Watson
Journal:  J Hypertens       Date:  2017-03       Impact factor: 4.844

4.  Blood pressure measurements and hypertension in infants, children, and adolescents: from the postmercury to mobile devices.

Authors:  Seon Hee Lim; Seong Heon Kim
Journal:  Clin Exp Pediatr       Date:  2021-09-15

5.  Diagnostic accuracy of mercurial versus digital blood pressure measurement devices: a systematic review and meta-analysis.

Authors:  Malaisamy Muniyandi; Senthil Sellappan; Vidya Chellaswamy; Karunya Ravi; Sananthya Karthikeyan; Kannan Thiruvengadam; Jerard Maria Selvam; Nagarajan Karikalan
Journal:  Sci Rep       Date:  2022-03-01       Impact factor: 4.379

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.