Literature DB >> 21107544

Motor unit discharge rates of the anconeus muscle during high-velocity elbow extensions.

B Harwood1, A W Davidson, C L Rice.   

Abstract

Motor unit recruitment and motor unit discharge rate (MUDR) have been widely studied in isometric conditions but minimally during velocity-dependent contractions. For isometric contractions, surface electromyography (EMG) activity of the elbow extensors plateaus at near maximal torques (Le Bozec et al. 1980; Le Bozec and Maton 1982). One study (Maton and Bouisset 1975) recorded single motor unit (MU) activity at maximal velocities; however, only the rate of the first interspike interval (ISI) was reported and likely was not representative of the average MUDR of the MU train. The purpose was to calculate average MUDRs of the anconeus during loaded velocity-dependent contractions from zero velocity (isometric) up to maximal velocity (V(max25)) through a large range of motion. A Biodex dynamometer was used to record elbow extension torque, position, and velocity. Single MU potentials were collected from the anconeus with intramuscular EMG, and surface EMG was sampled from the lateral head of the triceps brachii during maximal voluntary isometric contractions (MVCs) and velocity-dependent contractions loaded at 25% MVC over 120° range of motion at five target velocities (0, 25, 50, 75, 100%V(max25)). Elbow extension velocities ranged from 93 to 494°/s and average MUDR ranged from 11.8 Hz at 25%MVC to 39.0 Hz at 100%V(max25.) Overall average MUDRs increased as a function of velocity, although the root mean square of triceps brachii surface EMG plateaued at 50%V(max25). Piecewise regression analysis revealed two distinct linear ranges each described by a unique equation, suggesting that MUDRs of the anconeus enter a secondary range of firing, characterized by a steeper slope as velocity approaches maximum.

Mesh:

Year:  2010        PMID: 21107544     DOI: 10.1007/s00221-010-2463-4

Source DB:  PubMed          Journal:  Exp Brain Res        ISSN: 0014-4819            Impact factor:   1.972


  61 in total

1.  Rhythmic properties of motoneurones innervating muscle fibres of different speed in m. gastrocnemius medialis of the cat.

Authors:  D Kernell
Journal:  Brain Res       Date:  1979-01-05       Impact factor: 3.252

2.  Firing rates of motor units during strong dynamic contractions.

Authors:  Alejandro Del Valle; Christine K Thomas
Journal:  Muscle Nerve       Date:  2005-09       Impact factor: 3.217

3.  Motor unit activation patterns during concentric wrist flexion in humans with different muscle fibre composition.

Authors:  K Søgaard; H Christensen; N Fallentin; M Mizuno; B Quistorff; G Sjøgaard
Journal:  Eur J Appl Physiol Occup Physiol       Date:  1998-10

Review 4.  Neural strategies in the control of muscle force.

Authors:  R M Enoka
Journal:  Muscle Nerve Suppl       Date:  1997

5.  Differences between motor unit firing rate, twitch characteristics and fibre type composition in an agonistic muscle group in man.

Authors:  S Le Bozec; B Maton
Journal:  Eur J Appl Physiol Occup Physiol       Date:  1987

6.  The number of active motor units and their firing rates in voluntary contraction of human brachialis muscle.

Authors:  K Kanosue; M Yoshida; K Akazawa; K Fujii
Journal:  Jpn J Physiol       Date:  1979

7.  Motor unit activity during human single joint movements.

Authors:  S J Garland; J D Cooke; K J Miller; T Ohtsuki; T Ivanova
Journal:  J Neurophysiol       Date:  1996-09       Impact factor: 2.714

8.  The activity of anconeus during voluntary elbow extension: the effect of lidocaine blocking of the muscle.

Authors:  S Le Bozec; B Maton
Journal:  Electromyogr Clin Neurophysiol       Date:  1982 May-Jun

9.  Changes in single motor unit behaviour contribute to the increase in contraction speed after dynamic training in humans.

Authors:  M Van Cutsem; J Duchateau; K Hainaut
Journal:  J Physiol       Date:  1998-11-15       Impact factor: 5.182

Review 10.  Active properties of motoneurone dendrites: diffuse descending neuromodulation, focused local inhibition.

Authors:  C J Heckman; Allison S Hyngstrom; Michael D Johnson
Journal:  J Physiol       Date:  2007-10-18       Impact factor: 5.182

View more
  7 in total

1.  Motor unit properties from three synergistic muscles during ramp isometric elbow extensions.

Authors:  B Harwood; B H Dalton; G A Power; C L Rice
Journal:  Exp Brain Res       Date:  2013-10-01       Impact factor: 1.972

2.  In vivo measurement of fascicle length and pennation of the human anconeus muscle at several elbow joint angles.

Authors:  Daniel E Stevens; Cameron B Smith; Brad Harwood; Charles L Rice
Journal:  J Anat       Date:  2014-09-16       Impact factor: 2.610

3.  The relationship of agonist muscle single motor unit firing rates and elbow extension limb movement kinematics.

Authors:  Eric A Kirk; Charles L Rice
Journal:  Exp Brain Res       Date:  2021-07-08       Impact factor: 1.972

4.  The anconeus-triceps lateral flap approach for total elbow arthroplasty in rheumatoid arthritis.

Authors:  A Celli; P Bonucci
Journal:  Musculoskelet Surg       Date:  2016-11-30

Review 5.  Neural Contributions to Muscle Fatigue: From the Brain to the Muscle and Back Again.

Authors:  Janet L Taylor; Markus Amann; Jacques Duchateau; Romain Meeusen; Charles L Rice
Journal:  Med Sci Sports Exerc       Date:  2016-11       Impact factor: 5.411

6.  Potentiation of isokinetic torque is velocity-dependent following an isometric conditioning contraction.

Authors:  Atsuki Fukutani; Naokazu Miyamoto; Hiroaki Kanehisa; Toshimasa Yanai; Yasuo Kawakami
Journal:  Springerplus       Date:  2013-10-22

7.  Model-based analysis of fatigued human knee extensors : Effects of isometrically induced fatigue on Hill-type model parameters and ballistic contractions.

Authors:  Harald Penasso; Sigrid Thaller
Journal:  Eur J Appl Physiol       Date:  2018-05-05       Impact factor: 3.078

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.