Literature DB >> 21107463

Effect of sustained elevated temperature prior to amplification on template copy number estimation using digital polymerase chain reaction.

Somanath Bhat1, Jacob L H McLaughlin, Kerry R Emslie.   

Abstract

Digital polymerase chain reaction (dPCR) has the potential to enable accurate quantification of target DNA copy number provided that all target DNA molecules are successfully amplified. Following duplex dPCR analysis from a linear DNA target sequence that contains single copies of two independent template sequences, we have observed that amplification of both templates in a single partition does not always occur. To investigate this finding, we heated the target DNA solution to 95 °C for increasing time intervals and then immediately chilled on ice prior to preparing the dPCR mix. We observed an exponential decline in estimated copy number (R(2)≥ 0.98) of the two template sequences when amplified from either a linearized plasmid or a 388 base pair (bp) amplicon containing the same two template sequences. The distribution of amplifiable templates and the final concentration (copies per µL) were both affected by heat treatment of the samples at 95 °C from 0 s to 30 min. The proportion of target sequences from which only one of the two templates was amplified in a single partition (either 1507 or hmg only) increased over time, while the proportion of target sequences where both templates were amplified (1507 and hmg) in each individual partition declined rapidly from 94% to 52% (plasmid) and 88% to 31% (388 bp amplicon) suggesting an increase in number of targets from which both templates no longer amplify. A 10 min incubation at 95 °C reduced the initial amplifiable template concentration of the plasmid and the 388 bp amplicon by 59% and 91%, respectively. To determine if a similar decrease in amplifiable target occurs during the default pre-activation step of typical PCR amplification protocol, we used mastermixes with a 20 s or 10 min hot-start. The choice of mastermix and consequent pre-activation time did not affect the estimated plasmid concentration. Therefore, we conclude that prolonged exposure of this DNA template to elevated temperatures could lead to significant bias in dPCR measurements. However, care must be taken when designing PCR and non-PCR based experiments by reducing exposure of the DNA template to sustained elevated temperatures in order to improve accuracy in copy number estimation and concentration determination.

Mesh:

Substances:

Year:  2010        PMID: 21107463     DOI: 10.1039/c0an00484g

Source DB:  PubMed          Journal:  Analyst        ISSN: 0003-2654            Impact factor:   4.616


  11 in total

Review 1.  A review on microscale polymerase chain reaction based methods in molecular diagnosis, and future prospects for the fabrication of fully integrated portable biomedical devices.

Authors:  Nae Yoon Lee
Journal:  Mikrochim Acta       Date:  2018-05-08       Impact factor: 5.833

2.  Genomic profiling of canine mast cell tumors identifies DNA copy number aberrations associated with KIT mutations and high histological grade.

Authors:  Hiroyuki Mochizuki; Rachael Thomas; Scott Moroff; Matthew Breen
Journal:  Chromosome Res       Date:  2017-01-05       Impact factor: 5.239

3.  Denaturation-Enhanced Droplet Digital PCR for Liquid Biopsies.

Authors:  Mariana Fitarelli-Kiehl; Fangyan Yu; Ravina Ashtaputre; Ka Wai Leong; Ioannis Ladas; Julianna Supplee; Cloud Paweletz; Devarati Mitra; Jonathan D Schoenfeld; Sareh Parangi; G Mike Makrigiorgos
Journal:  Clin Chem       Date:  2018-10-01       Impact factor: 8.327

4.  Assessing the accuracy of quantitative molecular microbial profiling.

Authors:  Denise M O'Sullivan; Thomas Laver; Sasithon Temisak; Nicholas Redshaw; Kathryn A Harris; Carole A Foy; David J Studholme; Jim F Huggett
Journal:  Int J Mol Sci       Date:  2014-11-21       Impact factor: 5.923

Review 5.  Fundamentals of multiplexing with digital PCR.

Authors:  Alexandra S Whale; Jim F Huggett; Svilen Tzonev
Journal:  Biomol Detect Quantif       Date:  2016-05-27

Review 6.  dPCR: A Technology Review.

Authors:  Phenix-Lan Quan; Martin Sauzade; Eric Brouzes
Journal:  Sensors (Basel)       Date:  2018-04-20       Impact factor: 3.576

7.  Methods for applying accurate digital PCR analysis on low copy DNA samples.

Authors:  Alexandra S Whale; Simon Cowen; Carole A Foy; Jim F Huggett
Journal:  PLoS One       Date:  2013-03-05       Impact factor: 3.240

8.  A highly sensitive and specific method for the screening detection of genetically modified organisms based on digital PCR without pretreatment.

Authors:  Wei Fu; Pengyu Zhu; Chenguang Wang; Kunlun Huang; Zhixin Du; Wenying Tian; Qin Wang; Huiyu Wang; Wentao Xu; Shuifang Zhu
Journal:  Sci Rep       Date:  2015-08-04       Impact factor: 4.379

9.  Assessment of the real-time PCR and different digital PCR platforms for DNA quantification.

Authors:  Jernej Pavšič; Jana Žel; Mojca Milavec
Journal:  Anal Bioanal Chem       Date:  2015-10-31       Impact factor: 4.142

10.  Quantification of plasmid DNA reference materials for Shiga toxin-producing Escherichia coli based on UV, HR-ICP-MS and digital PCR.

Authors:  Wen Liang; Li Xu; Zhiwei Sui; Yan Li; Lanying Li; Yanli Wen; Chunhua Li; Shuzhen Ren; Gang Liu
Journal:  Chem Cent J       Date:  2016-09-12       Impact factor: 4.215

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.