Literature DB >> 21104169

Comparison of left ventricular functional parameters obtained from three different commercial automated software cardiac quantification program packages and their intraobserver reproducibility.

Zeki Dostbil1, Zuhal Arıtürk, Habib Cil, Mehmet Ali Elbey, Ebru Tekbaş, Mehmet Yazıcı, Ismail Yıldız, Bekir Taşdemir.   

Abstract

OBJECTIVE: ECG-gated myocardial perfusion scintigraphy (MPS) can be used to determine several cardiac functional parameters (e.g., left ventricular ejection fraction (LVEF), end-diastolic volume (EDV), and end-systolic volume (ESV)). In this study, we aimed to compare these cardiac functional parameters calculated by the following cardiac quantification programs: Emory Cardiac Toolbox (ECTb), Quantitative Gated SPECT (QGS), and Myometrix. We also evaluated reproducibility of the cardiac programs.
METHODS: Fifty-seven patients (27 male, 30 female) at Elazig Research and Training Hospital from 2008 to 2009 were included in this study. In all patients, (99m)Tc-MIBI ECG-Gated (8-bin frame mode) myocardial perfusion scintigraphies were performed. By using 3 different cardiac quantification programs (ECTb, QGS, and Myometrix); LVEF, EDV, and ESV were calculated. The same raw data of MPS images were reprocessed at different time periods, and these 3 parameters were recalculated. LVEF, EDV, and ESV yielded by 3 different programs were compared for interprogram variability assessment, and parameters calculated at two different time periods were compared to evaluate intraprogram reproducibility.
RESULTS: There were statistically significant differences between ECTb, QGS, and Myometrix programs for LVEF, EDV, and ESV (p < 0.001). There was also a statistically significant correlation between LVEF and EDV (p < 0.001, r = 0.546; p < 0.001, r = 0.45, respectively), but no statistically significant correlation was present between the ESV values (p > 0.05, r = 0.09). Statistically significant differences were not found between the values of LVEF, EDV, and ESV obtained from the first and second reconstruction analysis of 3 cardiac quantification programs. DISCUSSION: Different MPS cardiac software programs give variable (but correlated) LVEF and left ventricular volumetric measures. Those obtained from different cardiac softwares cannot be used interchangeably. Our findings have shown that ECTb, QGS, and Myometrix programs are reproducible, with respect to LVEF, EDV, and ESV.

Entities:  

Mesh:

Year:  2010        PMID: 21104169     DOI: 10.1007/s12149-010-0435-1

Source DB:  PubMed          Journal:  Ann Nucl Med        ISSN: 0914-7187            Impact factor:   2.668


  1 in total

1.  Myocardial perfusion and left ventricular quantitative parameters obtained using gated myocardial SPECT: Comparison of three software packages.

Authors:  Sotiria Alexiou; Panagiotis Georgoulias; George Angelidis; Varvara Valotassiou; Ioannis Tsougos; Dimitrios Psimadas; Velissarios Lakiotis; Agaristi Kaspiri; Dimitrios Alexopoulos; Dimitrios Apostolopoulos; Pavlos Vassilakos
Journal:  J Nucl Cardiol       Date:  2016-11-21       Impact factor: 5.952

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.