Literature DB >> 21103692

Arteriovenous fistula cannulation by buttonhole technique using dull needle.

Manuel Carlos Martins de Castro1, Celina de Fátima e Silva, João Marcos Rodrigues de Souza, Maria Cristina Silva Brotero de Assis, Maria Valéria da Silva Aoki, Magdaleni Xagoraris, Jerônimo Ruiz Centeno, José Adilson Camargo de Souza.   

Abstract

INTRODUCTION: Cannulation of arteriovenous fistula (AVF) may be performed by the following techniques: area puncture, rope ladder, or buttonhole. The ideal technique has not yet been established.
OBJECTIVE: To assess the complications and difficulties of introducing the buttonhole (BH) technique for cannulation of AVF created with a native vein in a dialysis unit.
METHODS: Sixteen patients (mean age, 57 ± 14 years) undergoing hemodialysis for 63 ± 38 months were changed to BH AVF cannulation. In the phase of track formation cannulations were performed with sharp needles and, in the maintenance phase, with blunt needles. In both phases, patients were assessed for pain intensity on a 0 to 10 scale.
RESULTS: The number of HD sessions required for the track formation was 9.5 ± 1.5 and the number of sessions during the maintenance phase was 29.7 ± 0.8 per patient. During the 152 HD for the track formation, no significant complications occurred. During the 475 HD sessions using the BH technique and a blunt needle, the complications were as follows: resistance to cannulation (7.6%); cannulation using a sharp needle due to cannulator choice (5.7%); change from a blunt to a sharp needle during cannulation (4.2%); and local bleeding (0.8%). One patient required antibiotic therapy. The median pain intensity reported by the patients was four during the track formation, and two during cannulation with a blunt needle. The Kt/V values before and after changing the cannulation technique did not differ (1.48 ± 0.27 and 1.48 ± 0.23).
CONCLUSION: The introduction of the BH technique with a blunt needle is technically easy, has few complications, reduces pain, and does not induce change in dialysis dose.

Entities:  

Mesh:

Year:  2010        PMID: 21103692

Source DB:  PubMed          Journal:  J Bras Nefrol        ISSN: 0101-2800


  4 in total

1.  Should buttonhole cannulation be discontinued?

Authors:  Louise M Moist; Gihad E Nesrallah
Journal:  Clin J Am Soc Nephrol       Date:  2013-12-26       Impact factor: 8.237

2.  A randomized trial comparing buttonhole with rope ladder needling in conventional hemodialysis patients.

Authors:  Jennifer M MacRae; Sofia B Ahmed; Rajneet Atkar; Brenda R Hemmelgarn
Journal:  Clin J Am Soc Nephrol       Date:  2012-07-19       Impact factor: 8.237

3.  Vascular access cannulation in hemodialysis patients: technical approach.

Authors:  Manuel Carlos Martins Castro; Francisca Tokiko Yanagida Carlquist; Celina de Fátima Silva; Magdaleni Xagoraris; Jerônimo Ruiz Centeno; José Adilson Camargo de Souza
Journal:  J Bras Nefrol       Date:  2019-12-09

4.  Cannulation technique and complications in arteriovenous fistulas: a Swedish Renal Registry-based cohort study.

Authors:  Karin Staaf; Anders Fernström; Fredrik Uhlin
Journal:  BMC Nephrol       Date:  2021-07-07       Impact factor: 2.388

  4 in total