Literature DB >> 21098914

Integration of the denoising, inpainting and local harmonic B(z) algorithm for MREIT imaging of intact animals.

Kiwan Jeon1, Hyung Joong Kim, Chang-Ock Lee, Jin Keun Seo, Eung Je Woo.   

Abstract

Conductivity imaging based on the current-injection MRI technique has been developed in magnetic resonance electrical impedance tomography. Current injected through a pair of surface electrodes induces a magnetic flux density distribution inside an imaging object, which results in additional magnetic field inhomogeneity. We can extract phase changes related to the current injection and obtain an image of the induced magnetic flux density. Without rotating the object inside the bore, we can measure only one component B(z) of the magnetic flux density B = (B(x), B(y), B(z)). Based on a relation between the internal conductivity distribution and B(z) data subject to multiple current injections, one may reconstruct cross-sectional conductivity images. As the image reconstruction algorithm, we have been using the harmonic B(z) algorithm in numerous experimental studies. Performing conductivity imaging of intact animal and human subjects, we found technical difficulties that originated from the MR signal void phenomena in the local regions of bones, lungs and gas-filled tubular organs. Measured B(z) data inside such a problematic region contain an excessive amount of noise that deteriorates the conductivity image quality. In order to alleviate this technical problem, we applied hybrid methods incorporating ramp-preserving denoising, harmonic inpainting with isotropic diffusion and ROI imaging using the local harmonic B(z) algorithm. These methods allow us to produce conductivity images of intact animals with best achievable quality. We suggest guidelines to choose a hybrid method depending on the overall noise level and existence of distinct problematic regions of MR signal void.

Entities:  

Mesh:

Year:  2010        PMID: 21098914     DOI: 10.1088/0031-9155/55/24/010

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  3 in total

1.  Multishot echo-planar MREIT for fast imaging of conductivity, current density, and electric field distributions.

Authors:  Munish Chauhan; Rohini Vidya Shankar; Neeta Ashok Kumar; Vikram D Kodibagkar; Rosalind Sadleir
Journal:  Magn Reson Med       Date:  2017-02-16       Impact factor: 4.668

2.  CoReHA 2.0: a software package for in vivo MREIT experiments.

Authors:  Kiwan Jeon; Chang-Ock Lee
Journal:  Comput Math Methods Med       Date:  2013-02-24       Impact factor: 2.238

3.  Conductivity image enhancement in MREIT using adaptively weighted spatial averaging filter.

Authors:  Tong In Oh; Hyung Joong Kim; Woo Chul Jeong; Hun Wi; Oh In Kwon; Eung Je Woo
Journal:  Biomed Eng Online       Date:  2014-06-26       Impact factor: 2.819

  3 in total