Literature DB >> 21098499

Technique of reversed flared iliac stent graft for iliac aneurysms with discrepant size diameters.

Adam H Power1, Javairiah Fatima, Crystal Kavanagh, Gustavo S Oderich.   

Abstract

PURPOSE: Endovascular treatment of iliac artery aneurysms (IAAs) in patients with discrepancy in iliac artery diameters can be challenging because of limited availability of reversed flared stent graft limbs. The authors describe the technique of reversing a Cook Zenith (Bloomington, IN) iliac stent graft extension to accommodate for significant discrepancy in diameter between the common iliac artery (18 mm) and the external iliac artery (11 mm). TECHNIQUE: A 75-year-old male patient with a 7.3-cm right internal IAA was treated with endovascular exclusion of distal internal iliac artery branches using Amplatzer plugs (AGA Medical Corp, Plymouth, MN) and coverage of the internal iliac artery origin using a reversed 12 × 20 mm Cook Zenith TLFE Iliac extension limb (Bloomington, IN). The 12 × 20 mm iliac extension limb was unsheathed on-site using a strict sterile technique, reversed within the introducer and resheathed. Following percutaneous bilateral femoral access and exclusion of the anterior and posterior divisional branches of the internal iliac artery, the reversed flared iliac limb device was deployed from the distal common to the external iliac artery. Completion angiography and follow-up computed tomography angiography revealed no endoleak. The patient was dismissed on postoperative day 1 without complications.
CONCLUSION: The technique of reversed flared iliac stent graft limb is a feasible option in patients with iliac aneurysms and significant discrepancy in the diameter of the iliac arteries.

Entities:  

Mesh:

Year:  2010        PMID: 21098499     DOI: 10.1177/1531003510386495

Source DB:  PubMed          Journal:  Perspect Vasc Surg Endovasc Ther        ISSN: 1521-5768


  3 in total

1.  Fate of Aneurysmal Common Iliac Artery Landing Zones Used for Endovascular Aneurysm Repair.

Authors:  Claire L Griffin; Salvatore T Scali; Robert J Feezor; Catherine K Chang; Kristina A Giles; Javairiah Fatima; Thomas S Huber; Adam W Beck
Journal:  J Endovasc Ther       Date:  2015-08-19       Impact factor: 3.487

2.  Filament inadequate wall apposition of the different ends of flow diverters in the abdominal aorta of rabbits.

Authors:  Kuizhong Wang; Peng Jin; Peigang Lu; Qiang Liu; Bo Li; Zhenqiang Hao
Journal:  Neuroradiol J       Date:  2019-11-27

3.  Use of Reversed Iliac Leg Stent-Graft for the Treatment of Isolated Aneurysm of Internal Iliac Artery.

Authors:  Kyung Sup Song; Hyunsil Lee; Deok Ho Nam; Ki Hyuk Park; Sang-Seob Yun; Bae Young Lee; Kang Hoon Lee
Journal:  Vasc Specialist Int       Date:  2014-03-30
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.