Literature DB >> 21098495

Long-term follow-up after endovascular aneurysm repair: is ultrasound alone enough?

Andrew M Bakken1, Karl A Illig.   

Abstract

In the last decade, endovascular aneurysm repair (EVAR) has become the preferred method for infrarenal abdominal aortic aneurysm repair in patients with suitable anatomy. EVAR offers the advantage of lower perioperative morbidity and mortality but carries the cost of device-related complications such as endoleak, graft migration, graft thrombosis, and structural graft failure. These complications mandate a lifelong surveillance of EVAR patients and their endografts. Since the advent of EVAR, this has largely been accomplished with serial computed tomography (CT). There is, however, increasing awareness of the risks and costs of a lifelong CT imaging mandate, which has led to several cohort analyses comparing CT with color duplex ultrasonography (CDU) with contrast-enhanced ultrasound (CEUS) for the evaluation of the endograft and aneurysm sac post-EVAR. This review will summarize the findings of these reports and highlight the results of recent ultrasound-based surveillance strategies.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 21098495     DOI: 10.1177/1531003510382664

Source DB:  PubMed          Journal:  Perspect Vasc Surg Endovasc Ther        ISSN: 1521-5768


  3 in total

Review 1.  Ultrasonography for endoleak detection after endoluminal abdominal aortic aneurysm repair.

Authors:  Iosief Abraha; Maria Laura Luchetta; Rita De Florio; Francesco Cozzolino; Giovanni Casazza; Piergiorgio Duca; Basso Parente; Massimiliano Orso; Antonella Germani; Paolo Eusebi; Alessandro Montedori
Journal:  Cochrane Database Syst Rev       Date:  2017-06-09

2.  What is the role of contrast-enhanced ultrasound in the evaluation of the endoleak of aortic endoprostheses? A comparison between CEUS and CT on a widespread scale.

Authors:  E David; V Cantisani; H Grazhdani; L Di Marzo; L Venturini; F Fanelli; M Di Segni; N Di Leo; L Brunese; F Calliada; M Ciccariello; A Bottari; G Ascenti; F D'Ambrosio
Journal:  J Ultrasound       Date:  2016-11-23

3.  Contrast-enhanced Ultrasound in Detecting Endoleaks with Failed Computed Tomography Angiography Diagnosis after Endovascular Abdominal Aortic Aneurysm Repair.

Authors:  Xiao Yang; Yue-Xin Chen; Bo Zhang; Yu-Xin Jiang; Chang-Wei Liu; Rui-Na Zhao; Qiong Wu; Da-Ming Zhang
Journal:  Chin Med J (Engl)       Date:  2015-09-20       Impact factor: 2.628

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.