Literature DB >> 21097309

Support system for the preventive diagnosis of hypertensive retinopathy.

Daniel Ortíz1, Mauricio Cubides, Andrés Suárez, Martha Zequera, Julián Quiroga, Jorge Gómez, Nubia Arroyo.   

Abstract

The changes in diameter of retinal vessels are an important sign of diseases such as hypertension, arteriosclerosis and diabetes. Obtaining precise measurements of vascular widths is a critical and demanding process in automated retinal image analysis. This paper presents the development of a prototype for measuring the vessel diameters to calculate the arteriovenous ratio (AVR) by using different techniques including Gabor wavelet, gradients, morphological operations and Niblack. The diameter measurement is based on the image skeleton and the perpendicular segment of the vessel. An executable tool is developed using MATLAB and the results are evaluated.

Entities:  

Mesh:

Year:  2010        PMID: 21097309     DOI: 10.1109/IEMBS.2010.5628047

Source DB:  PubMed          Journal:  Annu Int Conf IEEE Eng Med Biol Soc        ISSN: 2375-7477


  2 in total

1.  Artery/vein classification of retinal vessels using classifiers fusion.

Authors:  Samra Irshad; Xiao-Xia Yin; Yanchun Zhang
Journal:  Health Inf Sci Syst       Date:  2019-11-08

Review 2.  Decision support systems and applications in ophthalmology: literature and commercial review focused on mobile apps.

Authors:  Isabel de la Torre-Díez; Borja Martínez-Pérez; Miguel López-Coronado; Javier Rodríguez Díaz; Miguel Maldonado López
Journal:  J Med Syst       Date:  2014-12-04       Impact factor: 4.460

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.