Literature DB >> 21096726

Dry electrode bio-potential recordings.

Gaetano Gargiulo1, Paolo Bifulco, Alistair McEwan, Joubin Nasehi Tehrani, Rafael A Calvo, Maria Romano, Mariano Ruffo, Richard Shephard, Mario Cesarelli, Craig Jin, Armin Mohamed, André van Schaik.   

Abstract

As wireless bio-medical long term monitoring moves towards personal monitoring it demands very high input impedance systems capable to extend the reading of bio-signal during the daily activities offering a kind of "stress free", convenient connection, with no need for skin preparation. In particular we highlight the development and broad applications of our own circuits for wearable bio-potential sensor systems enabled by the use of an FET based amplifier circuit with sufficiently high impedance to allow the use of passive dry electrodes which overcome the significant barrier of gel based contacts. In this paper we present the ability of dry electrodes in long term monitoring of ECG, EEG and fetal ECG.

Mesh:

Year:  2010        PMID: 21096726     DOI: 10.1109/IEMBS.2010.5627359

Source DB:  PubMed          Journal:  Annu Int Conf IEEE Eng Med Biol Soc        ISSN: 2375-7477


  7 in total

1.  Design, fabrication and experimental validation of a novel dry-contact sensor for measuring electroencephalography signals without skin preparation.

Authors:  Lun-De Liao; I-Jan Wang; Sheng-Fu Chen; Jyh-Yeong Chang; Chin-Teng Lin
Journal:  Sensors (Basel)       Date:  2011-05-30       Impact factor: 3.576

2.  Exploring miniaturized EEG electrodes for brain-computer interfaces. An EEG you do not see?

Authors:  Martin G Bleichner; Micha Lundbeck; Matthias Selisky; Falk Minow; Manuela Jäger; Reiner Emkes; Stefan Debener; Maarten De Vos
Journal:  Physiol Rep       Date:  2015-04

3.  Forcecardiography: A Novel Technique to Measure Heart Mechanical Vibrations onto the Chest Wall.

Authors:  Emilio Andreozzi; Antonio Fratini; Daniele Esposito; Ganesh Naik; Caitlin Polley; Gaetano D Gargiulo; Paolo Bifulco
Journal:  Sensors (Basel)       Date:  2020-07-13       Impact factor: 3.576

4.  A Piezoresistive Array Armband With Reduced Number of Sensors for Hand Gesture Recognition.

Authors:  Daniele Esposito; Emilio Andreozzi; Gaetano D Gargiulo; Antonio Fratini; Giovanni D'Addio; Ganesh R Naik; Paolo Bifulco
Journal:  Front Neurorobot       Date:  2020-01-17       Impact factor: 2.650

5.  Pregnancy detection and monitoring in cattle via combined foetus electrocardiogram and phonocardiogram signal processing.

Authors:  Gaetano D Gargiulo; Richard W Shephard; Jonathan Tapson; Alistair L McEwan; Paolo Bifulco; Mario Cesarelli; Craig Jin; Ahmed Al-Ani; Ning Wang; André van Schaik
Journal:  BMC Vet Res       Date:  2012-09-17       Impact factor: 2.741

6.  Design and assessment of a low-cost, electromyographically controlled, prosthetic hand.

Authors:  Massimo Polisiero; Paolo Bifulco; Annalisa Liccardo; Mario Cesarelli; Maria Romano; Gaetano D Gargiulo; Alistair L McEwan; Massimo D'Apuzzo
Journal:  Med Devices (Auckl)       Date:  2013-06-28

7.  True unipolar ECG machine for Wilson Central Terminal measurements.

Authors:  Gaetano D Gargiulo
Journal:  Biomed Res Int       Date:  2015-10-01       Impact factor: 3.411

  7 in total