Literature DB >> 21096445

Heart and respiratory rate detection on a bathroom scale based on the ballistocardiogram and the continuous wavelet transform.

Sonia Gilaberte1, Joan Gómez-Clapers, Ramon Casanella, Ramon Pallas-Areny.   

Abstract

Ballistocardiography is a non-invasive technique that yields information about the cardiovascular system that is not available in other external signals such as the electrocardiogram (ECG). In the last years, several research groups have obtained the ballistocardiogram (BCG) by using instrumentation methods simpler than those available in the 1950s and that did not progress because of their complexity as compared to ultrasound and other noninvasive techniques that are in common use nowadays. We describe a novel method for real-time robust heart- (HR) and respiratory- (RR) rate detection from a subject that stands on a common electronic bathroom scale. BCG signals from the scale are wirelessly sent to a PC where algorithms based on the continuous wavelet transform (CWT) extract the HR and the RR. HR results are compared to those obtained from the ECG. To better assess the RR results, subjects have been asked to synchronize their breathing rate to an on-screen bar-graph set at a constant rate of breaths per minute. This method to obtain the heart and respiratory rates is simple, compact, non-invasive and passive, and can be applied to any person able to stand on an electronic weighing scale, even if wearing shoes.

Entities:  

Mesh:

Year:  2010        PMID: 21096445     DOI: 10.1109/IEMBS.2010.5626866

Source DB:  PubMed          Journal:  Annu Int Conf IEEE Eng Med Biol Soc        ISSN: 2375-7477


  4 in total

1.  Classification of Decompensated Heart Failure From Clinical and Home Ballistocardiography.

Authors:  Varol Burak Aydemir; Supriya Nagesh; Md Mobashir Hasan Shandhi; Joanna Fan; Liviu Klein; Mozziyar Etemadi; James Alex Heller; Omer T Inan; James M Rehg
Journal:  IEEE Trans Biomed Eng       Date:  2019-08-15       Impact factor: 4.538

2.  Template-Based Statistical Modeling and Synthesis for Noise Analysis of Ballistocardiogram Signals: A Cycle-Averaged Approach.

Authors:  A Ozan Bicen; Daniel C Whittingslow; Omer T Inan
Journal:  IEEE J Biomed Health Inform       Date:  2018-09-19       Impact factor: 5.772

3.  Nonintrusive Remote Monitoring of Sleep in Home-Based Situation.

Authors:  Ibrahim Sadek; Mounir Mohktari
Journal:  J Med Syst       Date:  2018-03-01       Impact factor: 4.460

Review 4.  Physiological and Behavior Monitoring Systems for Smart Healthcare Environments: A Review.

Authors:  Mariana Jacob Rodrigues; Octavian Postolache; Francisco Cercas
Journal:  Sensors (Basel)       Date:  2020-04-12       Impact factor: 3.576

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.