Literature DB >> 21096304

Preliminary design of a simple passive toe exercise apparatus with a flexible metal hydride actuator for pressure ulcer prevention.

Shuichi Ino1, Mitsuru Sato, Minako Hosono, Sawako Nakajima, Kazuhiko Yamashita, Takashi Izumi.   

Abstract

In an aging society, social demands for home-based rehabilitation and assistive technologies by healthcare and welfare services are globally increasing. The progress of quality-of-life technologies and rehabilitation science is a very important and urgent issue for elderly and disabled individuals as well as for their caregivers. Thus, there is a substantial need to develop simple bedside apparatuses for both continuous exercise of joints and for power assistance for standing to prevent and manage disuse syndromes (e.g., pressure ulcers, joint contractures and muscular atrophy). Unfortunately, there are currently no commercially-available actuators compatible with the human requirements of flexibility, quietness, lightness and a high power-to-weight ratio. To fulfill the above demands, we have developed a novel actuation device using a metal hydride (MH) alloy and a laminate film, called the flexible MH actuator, as a human-friendly force generator for healthcare and welfare services. In this paper, we show the basic structure and characteristics of the flexible MH actuator used to create a passive exercise system for preventing disuse syndromes. To evaluate the efficiency of passive exercise for bedsore prevention, subcutaneous blood flow during passive exercise at common pressure-ulcer sites is measured by a laser blood flow meter. The force and range-of-motion angle required for a passive exercise apparatus is also examined with the help of a professional physical therapist. Based on these findings, a prototype of a passive exercise apparatus is fabricated using the flexible MH actuator technology, and its operation characteristics are preliminarily verified using a thermoelectric control system.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 21096304     DOI: 10.1109/IEMBS.2010.5627093

Source DB:  PubMed          Journal:  Annu Int Conf IEEE Eng Med Biol Soc        ISSN: 2375-7477


  1 in total

1.  Hydrogen-absorbing alloy-based metal-hydride actuation for application in rehabilitative systems.

Authors:  Kyong Kim; Seong Hyun Kim; Sung Hoon Kim; Chang Ho Yu
Journal:  Technol Health Care       Date:  2018       Impact factor: 1.285

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.