Literature DB >> 21096104

Is pulse transit time a good indicator of blood pressure changes during short physical exercise in a young population?

Jorge Proença1, Jens Muehlsteff, Xavier Aubert, Paulo Carvalho.   

Abstract

The Pulse Transit Time (PTT) is generally assumed to be a good surrogate measure to comfortably track blood pressure (BP) and blood pressure changes. This paper investigates PTT variations for healthy young subjects during a sequence of short-term physical exercises. PTT was measured by two different methodologies having different measurement accuracies as well as underlying assumptions: the total PTT from heart to fingertip and the difference of fingertip and earlobe PTTs. Small non consistent changes and very low correlation of both PTTs with systolic blood pressure (SBP) have been observed for the study population (-0.19 ± 0.45 and 0.22 ± 0.46). In conclusion, there might be a need for an improved measurement accuracy of the sensors and data processing techniques in use. The applicability of the Moens-Korteweg equation is also questionable for young people having flexible arteries. In this case, significant radius changes do occur in the large arteries during exercise, which might counteract a PTT decrease with the BP elevation. These radius effects are excluded from the Moens-Korteweg model.

Entities:  

Mesh:

Year:  2010        PMID: 21096104     DOI: 10.1109/IEMBS.2010.5626627

Source DB:  PubMed          Journal:  Annu Int Conf IEEE Eng Med Biol Soc        ISSN: 2375-7477


  12 in total

1.  Comparison of short-term heart rate variability indexes evaluated through electrocardiographic and continuous blood pressure monitoring.

Authors:  Riccardo Pernice; Michal Javorka; Jana Krohova; Barbora Czippelova; Zuzana Turianikova; Alessandro Busacca; Luca Faes
Journal:  Med Biol Eng Comput       Date:  2019-02-07       Impact factor: 2.602

2.  Analysis of Biosignals During Immersion in Computer Games.

Authors:  Mina Yeo; Seokbeen Lim; Gilwon Yoon
Journal:  J Med Syst       Date:  2017-11-17       Impact factor: 4.460

Review 3.  Cuffless Blood Pressure Monitoring: Academic Insights and Perspectives Analysis.

Authors:  Shiyun Li; Can Zhang; Zhirui Xu; Lihua Liang; Ye Tian; Long Li; Huaping Wu; Sheng Zhong
Journal:  Micromachines (Basel)       Date:  2022-07-30       Impact factor: 3.523

4.  Cuffless and Touchless Measurement of Blood Pressure from Ballistocardiogram Based on a Body Weight Scale.

Authors:  Shing-Hong Liu; Bing-Hao Zhang; Wenxi Chen; Chun-Hung Su; Chiun-Li Chin
Journal:  Nutrients       Date:  2022-06-20       Impact factor: 6.706

5.  Increasing accuracy of pulse transit time measurements by automated elimination of distorted photoplethysmography waves.

Authors:  Marit H N van Velzen; Arjo J Loeve; Sjoerd P Niehof; Egbert G Mik
Journal:  Med Biol Eng Comput       Date:  2017-03-30       Impact factor: 2.602

6.  Pulse Transit Time Based Continuous Cuffless Blood Pressure Estimation: A New Extension and A Comprehensive Evaluation.

Authors:  Xiaorong Ding; Bryan P Yan; Yuan-Ting Zhang; Jing Liu; Ni Zhao; Hon Ki Tsang
Journal:  Sci Rep       Date:  2017-09-14       Impact factor: 4.379

7.  Wearable Piezoelectric-Based System for Continuous Beat-to-Beat Blood Pressure Measurement.

Authors:  Ting-Wei Wang; Shien-Fong Lin
Journal:  Sensors (Basel)       Date:  2020-02-05       Impact factor: 3.576

8.  Combined deep CNN-LSTM network-based multitasking learning architecture for noninvasive continuous blood pressure estimation using difference in ECG-PPG features.

Authors:  Da Un Jeong; Ki Moo Lim
Journal:  Sci Rep       Date:  2021-06-29       Impact factor: 4.379

Review 9.  The use of photoplethysmography for assessing hypertension.

Authors:  Mohamed Elgendi; Richard Fletcher; Yongbo Liang; Newton Howard; Nigel H Lovell; Derek Abbott; Kenneth Lim; Rabab Ward
Journal:  NPJ Digit Med       Date:  2019-06-26

Review 10.  Multimodal Photoplethysmography-Based Approaches for Improved Detection of Hypertension.

Authors:  Kaylie Welykholowa; Manish Hosanee; Gabriel Chan; Rachel Cooper; Panayiotis A Kyriacou; Dingchang Zheng; John Allen; Derek Abbott; Carlo Menon; Nigel H Lovell; Newton Howard; Wee-Shian Chan; Kenneth Lim; Richard Fletcher; Rabab Ward; Mohamed Elgendi
Journal:  J Clin Med       Date:  2020-04-22       Impact factor: 4.241

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.