Capacitive driven-right-leg grounding in Indirect-contact ECG measurement.

Yong Gyu Lim1, Gih Sung Chung, Kwang Suk Park.   

Abstract

For the reduction of common-mode noise level in Indirect-contact ECG (IDC-ECG) measurement, a driven-right-leg grounding method was applied to the IDC-ECG. Because the IDC-ECG does not require any direct contact between the electrodes and the human skin, it is adequate for un-constraining long-term ECG measurement at home and its various applications are now under development. However, larger 60 Hz noise induced by power line appears in IDC-ECG than in conventional ECG, that is a restriction of IDC-ECG application. In this study, the driven-right-leg ground which has been used in conventional direct-contact ECG, was adapted to the IDC-ECG measurement, by feedback of the inversion of amplified common-mode noise to the body through the conductive textile laid on the chair seat. It was shown that the level of 60Hz power line noise was reduced to about -40 dB when the driven-right-leg gain was 1000.

Entities:  

Mesh:

Year:  2010        PMID: 21095911     DOI: 10.1109/IEMBS.2010.5626424

Source DB:  PubMed          Journal:  Annu Int Conf IEEE Eng Med Biol Soc        ISSN: 2375-7477


  5 in total

1.  Measurement of electrocardiograms in a bath through tap water utilizing capacitive coupling electrodes placed outside the bathtub wall.

Authors:  Kosuke Motoi; Yasuhiro Yamakoshi; Takehiro Yamakoshi; Hiroaki Sakai; Naoto Tanaka; Ken-Ichi Yamakoshi
Journal:  Biomed Eng Online       Date:  2017-01-11       Impact factor: 2.819

2.  Common-mode noise cancellation circuit for wearable ECG.

Authors:  Mutsumi Noro; Daisuke Anzai; Jianqing Wang
Journal:  Healthc Technol Lett       Date:  2017-04-20

3.  Development and Test of a Portable ECG Device with Dry Capacitive Electrodes and Driven Right Leg Circuit.

Authors:  Alessandro Zompanti; Anna Sabatini; Simone Grasso; Giorgio Pennazza; Giuseppe Ferri; Gianluca Barile; Massimo Chello; Mario Lusini; Marco Santonico
Journal:  Sensors (Basel)       Date:  2021-04-15       Impact factor: 3.576

4.  A Hygroscopic Sensor Electrode for Fast Stabilized Non-Contact ECG Signal Acquisition.

Authors:  Ee-May Fong; Wan-Young Chung
Journal:  Sensors (Basel)       Date:  2015-08-05       Impact factor: 3.576

5.  Two-Electrode ECG for Ambulatory Monitoring with Minimal Hardware Complexity.

Authors:  Branko Babusiak; Stefan Borik; Maros Smondrk
Journal:  Sensors (Basel)       Date:  2020-04-22       Impact factor: 3.576

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.