Literature DB >> 21095083

Use of prior mammograms in the transition to digital mammography: a performance and cost analysis.

S Taylor-Phillips1, M G Wallis, A Duncan, A G Gale.   

Abstract

Breast screening in Europe is gradually changing from film to digital imaging and reporting of cases. In the transition period prior mammograms (from the preceding screening round) are films thereby potentially causing difficulties in comparison to current digital mammograms. To examine this breast screening performance was measured at a digital mammography workstation with prior mammograms displayed in different formats, and the associated costs calculated. 160 selected difficult cases (41% malignant) were read by eight UK qualified mammography readers in three conditions: with film prior mammograms; with digitised prior mammograms; or without prior mammograms. Lesion location and probability of malignancy were recorded, alongside a decision of whether to recall each case for further tests. JAFROC analysis showed a difference between conditions (p=.006); performance with prior mammograms in either film or digitised formats was superior to that without prior mammograms (p<.05). There was no difference in the performance when the prior mammograms were presented in film or digitised form. The number of benign or normal cases recalled was 26% higher without prior mammograms than with digitised or film prior mammograms (p<.05). This would correspond to an increase in recall rate at the study hospital from 4.3% to 5.5% with no associated increase in cancer detection rate. The cost of this increase was estimated to be £11,581 (€13,666) per 10,000 women screened, which is higher than the cost of digitised (£11,114/€13,115), or film display (£6451/€7612) of the prior mammograms. It is recommended that, where available, prior mammograms are used in the transition to digital breast screening.
Copyright © 2010 Elsevier Ireland Ltd. All rights reserved.

Entities:  

Mesh:

Year:  2010        PMID: 21095083     DOI: 10.1016/j.ejrad.2010.10.025

Source DB:  PubMed          Journal:  Eur J Radiol        ISSN: 0720-048X            Impact factor:   3.528


  4 in total

Review 1.  The Empirical Foundations of Teleradiology and Related Applications: A Review of the Evidence.

Authors:  Rashid L Bashshur; Elizabeth A Krupinski; James H Thrall; Noura Bashshur
Journal:  Telemed J E Health       Date:  2016-09-01       Impact factor: 3.536

2.  Variations in breast cancer detection rates during mammogram-reading sessions: does experience have an impact?

Authors:  Abdulaziz S Alshabibi; Moayyad E Suleiman; Salman M Albeshan; Robert Heard; Patrick C Brennan
Journal:  Br J Radiol       Date:  2021-11-04       Impact factor: 3.039

3.  A cost analysis of a cancer genetic service model in the UK.

Authors:  Ingrid Slade; Helen Hanson; Angela George; Kelly Kohut; Ann Strydom; Sarah Wordsworth; Nazneen Rahman
Journal:  J Community Genet       Date:  2016-02-27

4.  Retrospective review of the drop in observer detection performance over time in lesion-enriched experimental studies.

Authors:  Sian Taylor-Phillips; Markus C Elze; Elizabeth A Krupinski; Kathryn Dennick; Alastair G Gale; Aileen Clarke; Claudia Mello-Thoms
Journal:  J Digit Imaging       Date:  2015-02       Impact factor: 4.056

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.