Literature DB >> 21094572

Application of rapid prototyping for temporomandibular joint reconstruction.

ShanYong Zhang1, XiuMing Liu, YuanJin Xu, Chi Yang, Gerhard Undt, MinJie Chen, Majd S Haddad, Bai Yun.   

Abstract

PURPOSE: To introduce the preliminary application of rapid prototyping (RP) for temporomandibular joint (TMJ) surgery.
MATERIALS AND METHODS: This study included 11 consecutive patients (13 joints) seeking TMJ replacement. All patients had previously undergone 3-dimensional computed tomography (CT) scanning (0.625-mm slice thickness) of the craniofacial skeleton. The data from CT scanning in DICOM (Digital Imaging and Communications in Medicine) format were input into the interactive Simplant CMF software program (Materialise Medical, Leuven, Belgium). Preoperative planning included segmentation and osteotomies. The movements of the jaw bones were simulated by use of Simplant CMF. The affected mandible was reconstructed based on the contralateral side. Then, the titanium plate was shaped on the reconstructed model before surgery. The bone graft was transplanted by the shaped titanium plate during the operation to reconstruct the TMJ. Twenty-four patients who underwent traditional surgery were used as the control group. The operative time of the 2 groups was analyzed with the SPSS software package, version 13.0 (SPSS, Chicago, IL), with the Student t test. The data from CT scanning in the experimental group before and after surgery were compared by paired t test.
RESULTS: All the incisions healed primarily without any complications. All patients were satisfied with the operation, because of their symmetric faces and good occlusion. Postoperative magnetic resonance imaging confirmed the position of the transplanted costochondral cartilage in the glenoid fossa. A group t test showed that the operative time was longer in the control group (mean, 7.09 hours) than that in the RP group (mean, 5.67 hours). Three parameters (condyle-incisor, condyle-mental foramen, and condyle-angle) from the postoperative CT scan were analyzed by paired t test, and there was no significant difference between the 2 sides.
CONCLUSION: RP technology provides an advanced method for TMJ reconstruction that can make the TMJ reconstruction more accurate and symmetric, improve the mandible's function, and consequently, enhance the reconstructive effect. Copyright Â
© 2011 American Association of Oral and Maxillofacial Surgeons. All rights reserved.

Entities:  

Mesh:

Year:  2010        PMID: 21094572     DOI: 10.1016/j.joms.2010.05.081

Source DB:  PubMed          Journal:  J Oral Maxillofac Surg        ISSN: 0278-2391            Impact factor:   1.895


  6 in total

1.  Medical 3D Printing Cost-Savings in Orthopedic and Maxillofacial Surgery: Cost Analysis of Operating Room Time Saved with 3D Printed Anatomic Models and Surgical Guides.

Authors:  David H Ballard; Patrick Mills; Richard Duszak; Jeffery A Weisman; Frank J Rybicki; Pamela K Woodard
Journal:  Acad Radiol       Date:  2019-09-18       Impact factor: 3.173

Review 2.  3D-printing techniques in a medical setting: a systematic literature review.

Authors:  Philip Tack; Jan Victor; Paul Gemmel; Lieven Annemans
Journal:  Biomed Eng Online       Date:  2016-10-21       Impact factor: 2.819

3.  Facial Reconstruction: A Systematic Review of Current Image Acquisition and Processing Techniques.

Authors:  Sam P Tarassoli; Matthew E Shield; Rhian S Allen; Zita M Jessop; Thomas D Dobbs; Iain S Whitaker
Journal:  Front Surg       Date:  2020-12-07

Review 4.  Comparing the use of conventional and three-dimensional printing (3DP) in mandibular reconstruction.

Authors:  Ailis Truscott; Reza Zamani; Mohammad Akrami
Journal:  Biomed Eng Online       Date:  2022-03-19       Impact factor: 2.819

5.  Rapid prototyping modelling in oral and maxillofacial surgery: A two year retrospective study.

Authors:  Anni Suomalainen; Patricia Stoor; Karri Mesimäki; Risto K Kontio
Journal:  J Clin Exp Dent       Date:  2015-12-01

6.  3D printing technology used in severe hip deformity.

Authors:  Shanshan Wang; Li Wang; Yan Liu; Yongfang Ren; Li Jiang; Yan Li; Hao Zhou; Jie Chen; Wenxiao Jia; Hui Li
Journal:  Exp Ther Med       Date:  2017-07-18       Impact factor: 2.447

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.