Literature DB >> 21094512

Analysis of PCDD/Fs and dioxin-like PCBs in atmospheric deposition samples from the Flemish measurement network: Optimization and validation of a new CALUX bioassay method.

K Croes1, K Van Langenhove, M Elskens, M Desmedt, E Roekens, A Kotz, M S Denison, W Baeyens.   

Abstract

Since the CALUX (Chemically Activated LUciferase gene eXpression) bioassay is a fast, sensitive and inexpensive tool for the analysis of a high number of samples, validation of new methods is urgently needed. In this study, a new method for the analysis of PCDD/Fs and dioxin-like PCBs in atmospheric deposition samples with the CALUX bioassay was developed, optimized and validated. The method consists of 4 steps: filtration, extraction, clean up and bioassay analysis. To avoid the use of large amounts of toxic solvents, new techniques were used for filtration and extraction: a C18 filter was used instead of a liquid/liquid extraction and an Accelerated Solvent Extractor (ASE) was used instead of the traditional soxhlet extraction. After pre-oxidation of the sample extract, clean up was done using a multi-layer silica gel column coupled to a carbon column. The PCDD/F and PCB fractions were finally analyzed with the H1L7.5c1 and/or the H1L6.1c3 mouse hepatoma cell lines. The limit of quantification was 1.4pg CALUX-BEQm(-2)d(-1) for the PCBs and 5.6pgCALUX-BEQm(-2)d(-1) for the PCDD/Fs, when using the new sensitive H1L7.5c1 cell line. The GC-HRMS recovery for all PCDD/F congeners was between 55% and 112%, with a mean recovery of 90%. CALUX recoveries of spiked procedural blanks were between the accepted ranges of 80-120%. Repeatability and reproducibility were satisfactory and no interferences from metals were detected. The first results from the Flemish measurement program showed good correlation between CALUX and GC-HRMS. Copyright Â
© 2010 Elsevier Ltd. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 21094512     DOI: 10.1016/j.chemosphere.2010.10.092

Source DB:  PubMed          Journal:  Chemosphere        ISSN: 0045-6535            Impact factor:   7.086


  6 in total

1.  Quantification of PCDD/Fs and dioxin-like PCBs in small amounts of human serum using the sensitive H1L7.5c1 mouse hepatoma cell line: optimization and analysis of human serum samples from adolescents of the Flemish human biomonitoring program FLEHS II.

Authors:  K Croes; K Van Langenhove; E Den Hond; L Bruckers; A Colles; G Koppen; I Loots; V Nelen; G Schoeters; T Nawrot; N Van Larebeke; M S Denison; T Vandermarken; M Elskens; W Baeyens
Journal:  Talanta       Date:  2011-08-05       Impact factor: 6.057

2.  Time-integrated monitoring of polychlorinated dibenzo-p-dioxins and polychlorinated dibenzofurans (PCDD/Fs) in urban and industrial wastewaters using a ceramic toximeter and the CALUX bioassay.

Authors:  Amr Addeck; Kim Croes; Kersten Van Langenhove; Michael S Denison; Ahmed Elhamalawy; Marc Elskens; Willy Baeyens
Journal:  Chemosphere       Date:  2013-09-25       Impact factor: 7.086

3.  Time-integrated monitoring of dioxin-like polychlorinated biphenyls (dl-PCBs) in aquatic environments using the ceramic toximeter and the CALUX bioassay.

Authors:  Amr Addeck; Kim Croes; Kersten Van Langenhove; Michael S Denison; Ahmed S Afify; Yue Gao; Marc Elskens; Willy Baeyens
Journal:  Talanta       Date:  2013-12-16       Impact factor: 6.057

4.  Assessment of dioxin-like activity in PM10 air samples from an industrial location in Algeria, using the DRE-CALUX bioassay.

Authors:  Sidali Khedidji; Kim Croes; Noureddine Yassaa; Riad Ladji; Michael S Denison; Willy Baeyens; Marc Elskens
Journal:  Environ Sci Pollut Res Int       Date:  2015-11-27       Impact factor: 4.223

5.  State of the art and advances in the impact assessment of dioxins and dioxin-like compounds.

Authors:  Marco Schiavon; Vincenzo Torretta; Elena Cristina Rada; Marco Ragazzi
Journal:  Environ Monit Assess       Date:  2015-12-24       Impact factor: 2.513

6.  A unifying review of bioassay-guided fractionation, effect-directed analysis and related techniques.

Authors:  Michael G Weller
Journal:  Sensors (Basel)       Date:  2012-07-04       Impact factor: 3.576

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.